Notice
The network cable must be disconnected in order to prevent transmission of the data.
Fig. 3: Graphical representation of the yield data in the Internet portal
3.6.3
RS485 bus
The inverter communicates with other devices via an RS485 bus. The following applies:
The inverter has two RS485 interfaces (RJ45 sockets) on the lower side of the casing.
n
The beginning and end of the RS485 bus must be terminated; see
n
Standard RJ45 cables can be used as bus cables (Cat-5 patch cables, not supplied). Use an alter-
n
native data connection cable for longer connections; see
The inverters connected to the RS485 bus operate as
n
Notice
The following inverters have compatible data interfaces and can be connected to the RS485 bus as
slaves:
StecaGrid 2020
StecaGrid 1800, 2300, 3010, 3000, 3600, 4200 and StecaGrid 1800x, 2300x, 3010x, 3600x,
4200x
StecaGrid 8000 3ph, StecaGrid 10000 3ph
StecaGrid 8000+ 3ph, StecaGrid 10000+ 3ph
Observe the manuals of these devices concerning the definition of addresses, termination and per-
missible data cables.
98
Ä 3.6.5, p. 101 .
Ä 3.6.4, p. 100 .
slaves.