Switching on the DC supply

112
3. Press rs to change the value.
4. Press SET. The change is adopted.
5. Repeat steps 1 to 4 for the other parameters.
6. Press ESC. The check list is shown.
1. The previously set reactive power characteristic curve is dis-
played graphically (example in Fig. left).
2. Press ESC. The check list is shown.
✔ Finish has been selected in the check list and SET has been
pressed. One of 2 possible dialogues is displayed.
1. Proceed as follows, depending on the respective dialogue:
Dialogue Settings are incomplete: Press SET and
n
and work through the open items in the check list.
Dialogue Are all settings correct?:
n
Press ESC to correct settings or
Press and hold SET (> 1 s) to finish initial commis-
sioning.
2. If SET was pressed for a longer time then the inverter starts
anew and synchronises itself with the grid (Fig. left).
u Set the DC circuit breaker on the inverter to position I (Fig.
left). After testing via the internal MSD (approx. 2 minutes),
the power fed into the grid can be shown on the display
(assuming that sunlight is present).
———————————————————————————
Notice
The DC circuit breaker on the coolcept-x devices can be
secured with a padlock to prevent unintentional switch-on
(maximum padlock size of 7 mm).
———————————————————————————