Connection Size 13...16
Install the braking resistor fire-
resistant and safe from touch!
GB
Provide suitable
protective measures for
the operation of the
frequency inverter!
E 12
L1
L1
L2
L2
L3
L3
PE
PE
Lay control and power lines separately!
The combination with frequency inverters allows only restricted use of standard
fault current (FI) - protective switches.
Neutralization as protective measure is prohibited at the output of the inverter,
see chapter Operating Specifications Fault Current Protective Switch!
The KEB COMBIVERT/COMBIDRIVE is designed for fixed connection, refer to
chapter Operating Specifications Connection Instructions!
Measures for radio interference suppression and interference suppressions are
listed in chapter Operating Specifications Interference Suppression!
Option (only for unit groups F1-K / F2)
Use the shortest possible twisted cables!
PA
PB
+
Charge
Control Circuit
U
V
M
W
~
3
PE
For protective measures
against radio interference
connect the shield to both
sides! In case of low-
frequency interferences
suppress the interference
according to VDE 0160!