14.4 Window open function / airing (AEr)

The MAX! Raditator Thermostat + automatically reduces
the temperature in the room during ventilation, in order to
save costs for heating. During ventilation, the window open
symbol (
Without MAX! Window Sensor:
The MAX! Radiator Thermostat + is able to automatically
detect a sharp fall in temperature during ventilation (tem-
perature fall detection). The temperature is then reduced
to 12°C (default factory setting) or the value as configured
for 15 minutes.
With MAX! Window Sensor:
When a MAX! Window Sensor is used, the opening and
closing of a window is detected at the precise time it occurs.
Whilst the window is open, the temperature is reduced to
the factory setting of 12°C or the value as configured. When
the MAX! Window Sensor detects the closing of the win-
dow, all MAX! Radiator Thermostat + installed in the room
are immediately reset to their original mode.
Adjust reduced temperature and duration:
A reduced temperature of 12° C and a duration of 15 mi-
nutes is set as default. Both values can be configured in-
dividually:
In the MAX! House Solution, all settings of the MAX!
Radiator Thermostat + are made via the MAX! soft-
ware.
In the MAX! Room Solution, all settings of the MAX!
Radiator Thermostat + are made via the MAX! Wall
Thermostat + .
78