Herunterladen Inhalt Inhalt Diese Seite drucken

Adapter Run - eQ-3 MAX! Bedienungsanleitung

Elektronischer funk-heizkörperthermostat
Vorschau ausblenden Andere Handbücher für MAX!:
Inhaltsverzeichnis

Werbung

Once the batteries have been inserted, the motor rever-
ses; meanwhile, "InS" and the activity symbol (
splayed. As soon as "InS" is displayed without the activity
), the MAX! Radiator Thermostat + can be moun-
symbol (
ted. This is followed by an adapter run ("AdA") to adapt the
thermostat to the valve.
• Attach the radiator thermostat to the valve.
• Tighten the union nut.
• Press the boost button when "InS" is displayed.
The actuator performs an adapter run. "AdA" and the activity
symbol (
) are displayed; during this time, operation is
not possible.
If the adapter run has been initiated prior to mounting or if
an error message (F1, F2, F3) is displayed, press the Boost
button; the motor reverses to the "InS" position.
If the MAX! Radiator Thermostat + has not been
taught-in to the MAX! Cube, the device automatic-
ally switches to manual operation (Manu).
Teach-in mode can be activated also while "InS" is
displayed.
62

8. Adapter run

) are di-