Open Window Function - eQ-3 MAX Bedienungsanleitung

Heizkörperthermostat
Vorschau ausblenden Andere Handbücher für MAX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• The remaining time for the function is counted down in
seconds ("300" to "000"). Whilst the function is active,
is displayed.
• The activity symbol (
justing pin opens/closes the valve.
• Once the set time has elapsed, the radiator thermostat
switches back to the mode that was active previously
(automatic/manual), with the temperature that was set
previously.
• The function can be deactivated prematurely at any time
by pressing the Boost button again.
The function will not have an immediate effect if the
radiator is covered or concealed (e.g. by a sofa).
If the duration of the boost function (e.g. via the MAX!
Cube) is set so that the display exceeds 999 seconds,
the display value switches from seconds to minutes.
The actuator reduces the temperature in the room auto-
matically during ventilation, in order to save on heating
costs. During ventilation, the window open symbol (
is displayed.
Without MAX! Window Sensor:
A MAX! Radiator Thermostat is able to automatically
detect a sharp fall in temperature caused by ventilation
(temperature fall detection). The temperature is then
reduced to 12°C or the value as configured in the software
for 15 minutes (default factory setting).
With MAX! Window Sensor:
When a MAX! Window Sensor is used, the opening and
) is displayed as long as the ad-

12. Open window function

)
39