Safety instructions for electrical connection
Danger due to electric shock when working on all electrical systems.
◆ The electrical connection for the tubular motor and all work on the electrical systems
may only be undertaken by an authorised qualified electrician and in accordance with
the connection diagrams in these instructions.
◆ Disconnect all poles from the mains and secure them against unintentional re-
connection.
◆ Check that the system is dead.
◆ Always undertake mounting and connection work with the equipment disconnected
from the mains power
Risk of short-circuit resulting from damaged cable.
◆ Lay all motor cables (13) so that they cannot be damaged by moving parts of the
awning.
◆ Lay the motor cable (13) in the empty tube up to the wall duct.
◆ Seal the wall duct after laying the motor cable (13) in order to prevent water
penetration.
◆ The mains connection for the drive may only be connected with the same conduction
type. Consult customer services if necessary.
The motor cable (Figure i)
9
38
1.
(7)
(13)
external switch
L
N
PE
Fixed-installation devices...
...must be equipped on the installation side with a circuit-breaker for each phase in
accordance with DIN VDE 0700. Switches with a contact opening width of min. 3 mm
can be used as circuit-breakers (e.g. power switch, power circuit breaker or residual-
current-operated circuit-breaker).
Risk of short-circuit resulting from water in the event of improper
cabling.
Never lay the motor cable (13) vertically upwards, as otherwise water may collect on the
cable and run into the motor, leading to damage. Lay the cable in a loop. The loop will
cause any water on the cable to collect at the lowest point, from where it can drain off.
STOP
Feed the motor cable (13) into the designated junction box or terminal
box after mounting the motor in place.
Colour scale for the motor leads (13)
=
external switch (white)
L
=
phase
(black)
N
=
neutral
(blue)
PE
=
earth
(green / yellow)
=
Antenna
(violet)
The antenna is integrated flush with the cable.