Connection and use of the cord circuit setting unit
for end point setting (Figures l / m )
12
(20)
13
40
Plunger
For initial installation, the roller shutter engineer can connect the motor cable (13) to a
commercially available cord switch device (20) (type no. 4090) in order to configure
the end points for the tubular motors.
After mounting, feed cables (e - h) for the motor cable (13) to the designated switching
point (e.g. up to the switch socket).
Use the "external switch" conductor (h).
If the conductor "external switch" (h) of motor cable (13) is connected to the "SET
button" of the cord circuit setting device (20), then you can use this set button to
configure the end points.
NOTE
Observe the various configuration options for the end points detailed in the "End point
adjustment" chapter (see below) and on the following pages.
Open the terminal contacts by pressing the plungers and connect all of
the wires of the motor cable (13) as follows:
Motor cable
> cord circuit setting device
Function
> Function
L
> L1 (direction of rotation 1)
External switch
> set line
N
> N
PE
> PE
After connection is completed, the buttons of the cord circuit setting
unit (20) will have the following functions:
ON
Rocker switch in central position = motor voltage off
ON
Rocker switch up (s)-position = motor voltage on
SET
SET-button = set button = retract awning/stop/extend/stop/etc.
IMPORTANT
The external switch lead (h) must be connected to neutral conductor (f)
after configuration of the end points (see fig. j).