Safety instructions for electrical connections

All work with electrical systems is endangered by electric shocks
which can be fatal.
◆ The tubular motor must only be connected to the mains and all work on electrical
equipment must only be carried out by a qualified electrician in accordance with
the diagrams provided in these instructions.
◆ Disconnect all poles of the mains cable from the mains and prevent them from
being switched on again.
◆ Check that the system has zero potential.
◆ Carry out all installation and connection works with all devices disconnected from the
mains.
there is a danger of short circuit if the cable is damaged.
◆ Make sure that all cables inside the roller shutter box are laid in such a way
that they cannot be damaged by moving parts.
◆ Only connect the mains cable for this drive to a similar type of cable. If in doubt,
contact our Customer Service department.
the motor cable ( Figure  )
9
52
1.
(11)
(15)
L1 (▲/▼)
L1 (▼/▲)
N
PE
In the case of stationary devices ...
...an energy isolating device must be provided for each phase during installation
in accordance with VDE 0700. Energy isolating devices include switches with a
contact opening gap of at least 3 mm (e.g. circuit breaker, fuses or residual current
circuit breakers).
Short circuit danger due to water if cables are not laid correctly.
Never lay the connecting cable (15) vertically upwards from the motor, or water may
run down the cable and into the motor, rendering it inoperable. Route the cable in a loop.
This allows the water to collect at the lowest point of the loop and drip down from there.
STOP
Insert the motor cable (15) into the distribution or switch box intended
for this purpose.
Motor cable (15) colour code
=
Setting wire
(white)
L1
=
Direction of rotation 1
(black)
L1
=
Direction of rotation 2
(brown)
N
=
Neutral
(blue)
PE
=
Earth connecting
(green/yellow)
(11)
=