General safety instructions
Danger due to electric shock when working on all electrical systems.
◆ The electrical connection for the tubular motor and all work on the electrical systems
may only be undertaken by an authorised qualified electrician and in accordance with
the connection diagrams in these instructions (see pages 38/39/40).
◆ Always undertake mounting and connection work with the equipment disconnected
from the mains power.
The use of defective equipment can lead to personal injury and damage
to property (electric shocks, short circuiting).
◆ Never use defective or damaged equipment.
◆ Check the drive and mains cable beforehand for damage.
◆ Consult our customer service department (see page 52) in the event that you discover
damage on the equipment.
i
Proper use / operational conditions
Only use the tubular motors for the electrical operation of awnings.
IMPORTANT
◆ The motor cable must be protected on the inside of the empty tube up to the junction
box under observation of local electrical regulations.
◆ Only use the manufacturer's original components and accessories.
Only use tubular motors which correspond to the local conditions in
terms of their output. Incorrectly dimensioned tubular motors can lead
to damage.
◆ Consult a specialist dealer when selecting the tubular motor and observe our tractive
force specifications on our Website: www.rademacher.de
i
Incorrect use
Using the tubular motor for purposes other than those stated above is
considered incorrect use.
i
Function of radio code
You can control the radio tubular motor directly using the radio code in order, for example, to
be also able to subsequently connect further DuoFern devices to the radio tubular motor
after installation. Once the connection has been successfully established, you can carry
out actions such as setting the limit stops for a radio tubular motor.
The radio code can be found on the enclosed label:
Example:
Incorrect use leads to an increased risk of injury.
◆ Train all personnel to safely use the tubular motor.
◆ Do not allow children or persons with limited capabilities to use the fixed control units
or remote control systems.
◆ Watch the moving awning and keep other people away from the area until the
movement has completed.
For awning systems which can be operated out of sight of the operator:
◆ Awnings may not be operated if work is being carried out nearby (e.g. windows
being cleaned).
For automatically actuated awnings:
◆ Awnings must be disconnected from the power supply if work is being carried out
nearby.
Regular maintenance of awnings increases operational reliability.
◆ Check the awnings regularly for poor balance or damaged lines and springs.
◆ Have damaged awnings repaired by a specialist firm.
Operating conditions
◆ A continuous 230 V / 50 Hz mains supply must be available at the site of installation
for the electrical connection in combination with on-site switchgear (fusing
◆ The installation and operation of the DuoFern radio system and its components is
only permitted for those systems and devices where a malfunction in the transmitter
or receiver would not cause a danger to personnel or property or where this risk is
already covered by other safety equipment.
Never use the DuoFern radio system or its components for:
systems with increased safety-relevant requirements or where there is an increased risk
of accidents. Such use would require additional safety equipment. Observe the respective
statutory regulations for the installation of such systems.
NOTE
Time window for activation via the radio code.
After switching on the power supply, the radio code is active for a maximum 2 hours. Once this
time has elapsed, activation using the radio code is no longer possible. Briefly disconnect
the environmental sensor from the mains to reactivate the time window.