Safety information regarding the electrical connection

Danger due to electric shock when working on all electrical systems.
◆ The electrical connection for the tubular motor and all work on the electrical systems
may only be undertaken by an authorised qualified electrician and in accordance with
the connection diagrams in these instructions.
◆ Disconnect all phases of the mains power supply cable and secure it to prevent any
unintended reconnection.
◆ Check the system for a zero-voltage status.
◆ Carry out all installation and connection work only in an isolated, zero-volts state.
Risk of short-circuit resulting from damaged cable.
◆ Lay all cables in the roller shutter box so that they cannot be damaged by moving
machinery.
◆ The mains connection for the drive may only be connected with the same conduction
type. Consult customer services if necessary.

The motor cable (Figure j )

10
42
(11)
(15)
external switch
L
N
PE
Antenna
Fixed-installation devices...
...must be equipped on the installation side with a circuit-breaker for each phase in
accordance with DIN VDE 0700. Switches with a contact opening width of min. 3 mm
can be used as circuit-breakers (e.g. power switch, power circuit breaker or residual-
current-operated circuit-breaker).
Risk of short-circuit resulting from water in the event of improper
cabling.
Never lay the motor cable (15) vertically upwards, as otherwise water may collect on the
cable and run into the motor, possibly leading to damage. Lay the cable in a loop. The loop
will cause any water on the cable to collect at the lowest point, from where it can drain off.
1.
Feed the motor cable (15) into the designated junction box or terminal
box after hooking the motor in place.
Colour scale for the motor leads (15)
=
external switch (white)
L
=
phase
N
=
neutral
PE
=
earth
=
Antenna
(11)
=
Set button on tubular motor
(black)
(blue)
(green / yellow)
(violet)