Herunterladen Inhalt Inhalt Diese Seite drucken

Probes For The Operating Medium Water And Oil; Probes For The Operating Medium Water, Oil And Air - JUMO DICON touch Kurzanleitung

Vorschau ausblenden Andere Handbücher für DICON touch:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4 Electrical connection
4.3.4

Probes for the operating medium water and oil

Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.
Actual type designation
RTD temperature probe Data Sheet 90.2006
90.2006/10-402-1003-1-9-100-104/000
90.2006/10-402-2003-1-9-100-104/000
902006/54-227-2003-1-15-710-254/000
902006/54-227-1003-1-15-710-254/000
902006/10-226-1003-1-9-250-104/000
902006/10-226-2003-1-9-250-104/000
Thermocouples Data Sheet 90.1006
901006/54-544-2043-15-710-254/000
901006/54-544-1043-15-710-254/000
901006/54-544-2042-15-710-254/000
901006/54-544-1042-15-710-254/000
Note: Because of the high response accuracy, only use thermowells (pockets) that are included in the scope of delivery.
Actual type designation
RTD temperature probe Data Sheet 90.2006
902006/53-505-2003-1-12-190-815/000
902006/53-507-2003-1-12-100-815/000
902006/53-507-2003-1-12-160-815/000
902006/53-507-2003-1-12-190-815/000
902006/53-507-2003-1-12-220-815/000
902006/53-507-1003-1-12-100-815/000
902006/53-507-1003-1-12-160-815/000
902006/53-507-1003-1-12-220-815/000
902006/53-505-1003-1-12-190-815/000
902006/53-505-3003-1-12-100-815/000
902006/53-505-3003-1-12-160-815/000
902006/53-505-3003-1-12-220-815/000
902006/40-226-1003-1-12-220-815/000
902006/40-226-1003-1-12-160-815/000
902006/40-226-1003-1-12-100-815/000
Thermocouples Data Sheet 90.1006
901006/53-543-1042-12-220-815/000
901006/53-543-2042-12-220-815/000
4.3.5

Probes for the operating medium water, oil and air

Note: Because of the high response accuracy, the use of thermowells (pockets) is not admissible.
Actual type designation
RTD temperature probe Data Sheet 90.2006
90.2006/10-390-1003-1-8-250-104/000
Thermocouples Data Sheet 90.1006
901006/45-551-2043-2-xxxx-11-xxxx
26
Old type
Probe type
designation
1 x Pt100
2 x Pt100
90.272-F02
2 x Pt100
90.272-F03
1 x Pt100
90.239
1 x Pt100
90-D-239
2 x Pt100
90.020-F02
2 x NiCr-Ni, Type „K"
90.020-F03
1 x NiCr-Ni, Type „K"
90.020-F12
2 x FeCuNi, Type „L"
90.020-F13
1 x FeCuNi, Type „L"
Old type
Probe type
designation
90D239-F03
2 x Pt100
90.239-F02
2 x Pt100
(arranged one
90.239-F12
below the other
in protection tube)
90.239-F22
90.239-F01
1 x Pt100
90.239-F11
90.239-F21
90.239-F03
1 x Pt100
90.239-F07
3 x Pt100
90.239-F17
90.239-F27
90.280-F30
1 x Pt100
90.280-F31
90.280-F32
90.111-F01
1 x Fe-CuNi Type „L"
90.111-F02
2 x Fe-CuNi Type „L"
Old type
Probe type
designation
90.210-F95
1 x Pt100
2 x NiCr-Ni, Typ „K"
Temperature range
Nom. length mm
-40 ... +400°C
100
100
-170 ... 550°C
65...670
65...670
-170 ... 480°C
250
250
-35 ... 550°C
65...670
65...670
65...670
65...670
Temperature range
Nom. length mm
-40 ... +400 °C
190
-40 ... +480 °C
100
160
190
220
-40 ... +480 °C
100
160
220
-40 ... +400 °C
190
-40 ... +400 °C
100
160
220
-170 ... +480°C
220
160
100
-35 ... 480°C
220
220
Temperature range
Install. length mm
max. 300°C
250
max. 1 50°C
50...2000
rocess connection
P
G1/2 screw connection
movable
G1/2 compression clamp
G1/2 screw connection
movable
G1/2 compression clamp
P
rocess connection
weld-in sleeve
weld-in sleeve
weld-in sleeve
P
rocess connection

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis