• To configure trigger threshold, trigger start edge, and trigger end edge
settings
Perform the following steps when "Period Sampling" is specified as the sampling mode.
1. Move the highlighting to "Threshold".
2. Press 1(EDIT) to display a dialog box for specifying the trigger threshold value, which is
value that data needs to attain before sampling starts.
3. Input the value you want.
4. Move the highlighting to "Start to".
5. Press one of the function keys described below.
To select this type of edge:
Falling
Rising
6. Move the highlighting to "End Edge".
7. Press one of the function keys described below.
To select this type of edge:
Falling
Rising
8. Press w to finalize Trigger Setup and return to the Sampling Config screen.
• To configure Photogate trigger start and end settings
Perform the following steps when CH1 is selected as a Photogate trigger source.
Perform the operation below even while Vernier Photogate is assigned to the SONIC
channel when performing Period Sampling with the EA-200.
1. Move the highlighting to "Start to".
2. Press one of the function keys described below.
To specify this Photogate status:
Photogate closed
Photogate open
3. Move the highlighting to "End Gate".
4. Press one of the function keys described below.
To specify this Photogate status:
Photogate closed
Photogate open
5. Press w to finalize Trigger Setup and return to the Sampling Config screen.
ε
-18
Configuring the Sampling Setup
Press this key:
1(Fall)
2(Rise)
Press this key:
1(Fall)
2(Rise)
Press this key:
1(Close)
2(Open)
Press this key:
1(Close)
2(Open)

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Fx-cg20Fx-cg20 auFx-cg10

Inhaltsverzeichnis