Test certificate
Tab. 11: Technical inverter data
The design of the inverter prevents it from causing DC leakage current.
1)
14.2

AC cables and line circuit breakers

Inverter
StecaGrid 3000 1.5 mm²
StecaGrid 3600 2.5 mm²
StecaGrid 4200 2.5 mm²
Tab. 12: Conductor cross-sections of the AC cables and suitable line circuit breakers
Power loss of the AC cables at the rated power of the inverter and a cable length of 10 m
1)
14.3

Table of countries

Details on setting the country are provided in Section 8.7, P. 69.
Note
The requirements for the country-specific grid parameters may change at short notice. Contact the
Steca Customer Service if the parameters specified in Tab. 13 no longer correspond to the legally
prescribed requirements in your country. See Section Contact, P. 88.
Country
Name
Display
Germany
4900 Deutschland
Sweden
4600 Sverige
France
3300 France
Portugal
35100 Portugal
Spain
3400 España
Netherlands
3100 Nederland
Belgium 1
3200 Belgique 1
Belgium 1 unlim-
3201 Belgique 1 unl
ited
Belgium 2
3202 Belgique 2
Belgium 2 unlim-
3203 Belgique 2 unl
ited
Austria
4300 Österreich
Italy 3
3902 Italia 3
Italy 6
3905 Italia 6
Slovenia
38600 Slovenija
Czech Republic
42000 Česko
Greek Islands
3001 Greece islands
Greek Mainland
3000 Greece conti-
nent
Australia
6100 Australia
Israel
9720 Israel
746.217 | 12.27
StecaGrid 3000
clearance certificate as per DIN VDE 0126-1-1, VDE AR N 4105, CE
symbol, G59, G83, DK 5940, UTE C 15-712-1, AS4777, CEI
AC cable conductor
Power loss
cross-section
40 W
2.5 mm²
24 W
4.0 mm²
15 W
37 W
4.0 mm²
23 W
49 W
4.0 mm²
31 W
Voltage disconnection
values (peak values)
upper
s
%
s
1)
60
15.0
0.20
30
15.0
0.20
30
15.0
0.20
20
15.0
0.20
180
10.0
0.20
30
10.0
2.00
30
10.0
0.10
5)
30
10.0
0.10
5)
30
15.0
0.20
5)
30
15.0
0.20
5)
30
15.0
0.20
30
22.0
0.10
30
15.0
0.20
30
15.0
0.20
30
15.0
0.20
180
15.0
0.50
180
15.0
0.50
60
17.0
2.00
300
17.0
2.00
StecaGrid 3600
0-21
Line circuit
breaker
B16
1)
B16 or B25
1)
B16 or B25
1)
B25
1)
B25
1)
B25
1)
B25
1)
Voltage disconnec-
tion values ø (average
2)
values)
lower
upper
%
s
%
s
−20
0.20
10 600.0
−15
0.20
6
60.0 −10 60.0
−15
0.20
10 600.0
−15
1.50
−15
0.20
−20
2.00
−26
0.10
– −15
−26
0.10
– −15
−20
0.20
10 600.0
−20
0.20
10 600.0
−20
0.20
12 600.0
−25
0.20
−15
0.40
10 600.0
−15
0.20
11
1.5
−15
0.20
10 600.0
−20
0.50
10 600.0
−20
0.50
10 600.0
−13
2.00
−13
2.00
StecaGrid 4200
Frequency discon-
nection values
3)
lower
upper
lower
%
s
Hz
s
Hz
1.5
0.2 −2.5
1.0
0.5 −3.0
0.2
0.2 −2.5
1.0
0.5 −3.0
1.0
0.2 −1.0
1.0
2.0 −2.0
1.5
0.5
0.1 −2.5
1.5
0.5
0.1 −2.5
0.5
0.2 −2.5
0.5
0.2 −2.5
1.0
0.2 −3.0
5.0
0.2 −5.0
1.5
0.1 −2.5
1.0
0.2 −3.0
0.5
0.2 −0.5
1.0
0.5 −2.5
0.5
0.5 −0.5
5.0
2.0 −5.0
5.0
2.0 −5.0
EN
4)
s
0.2
0.5
0.2
0.5
0.2
2.0
0.1
0.1
0.2
0.2
0.2
0.2
0.1
0.2
0.2
0.5
0.5
2.0
2.0
85

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Stecagrid 4200Stecagrid 3600

Inhaltsverzeichnis