2 Safety
The extraction of substances and materials which are combustible, aggressive, chemical or contain
oil vapors as well as aluminum or magnesium dusts can lead to fire and explosion due to chemical
reactions. Serious injuries and irreparable damage to the device can be the result.
► Only ever use the device as intended.
► Ensure that all components have been properly installed on the fume extraction torch.
► Ensure that the fume extraction torch is connected to the fume extraction system prior to use.
► Use the fume extraction torch only with a fume extraction system that has been approved for
use in the respective country.
► Observe the local occupational health and safety regulations and guidelines.
► Check the extraction hoses at regular intervals, at least once a week, for damage and
contamination.
► Note that the applied vacuum depends on the geographic altitude of the operation site.
► Observe the warning signals and indicators on the fume extraction system. Warning signals and
indicators can imply a saturated filter or a problem with/damage to the fume extraction torch.
► Replace the extraction-specific wear parts at regular intervals. The replacement interval
required depends on the application conditions.
► Opening the air regulator is only intended to briefly reduce the volume flow at the suction
nozzle. Close the air regulator immediately afterwards. The air regulator must be closed to
ensure efficient capture of fumes.
► Observe the fume extraction device setting information as shown on the sticker on the extraction
hose connection on the fume extraction torch cable assembly.
► When welding under particularly oily ambient conditions, creepage distances consisting of
metal oxides from the welding fume can form locally on fume-carrying surfaces, which are
potentially electrically conductive. Therefore, clean the welding fume-carrying surfaces on the
fume extraction torch regularly.
► Note that when additional exhaust air hoses or exhaust air hoses from other manufacturers are
used, there can be a loss of pressure in the fume extraction torch. The components connected
must be suitable for the device and guarantee the required minimum volume flow. Check the
components regularly or a proper fit, leaks and blockages due to dust deposits.
► Heed the requirements of DIN EN ISO 21904 as far as the minimum volume flow is concerned.
If the extraction volume flow is too high, this can lead to welding faults. Check the extraction
volume flow on the extraction nozzle with the aid of a suitable test rig (depending on the
manufacturer).
2.4.7

Safety instructions for emergencies

► In an emergency, immediately disconnect all supplies (for example electrical power supply,
coolant supply, compressed air supply, shielding gas supply).
► Extinguish burning oil or emulsions using a CO
EN - 50