10 Maintenance and Cleaning
10
Maintenance and Cleaning
Regular maintenance and cleaning are prerequisites for a long service life and perfect function. The
regular removal of dust can extend the service life of the filter cartridges. The maintenance interval
is determined by the working environment and operating time of the devices. If the device is
operated for longer than 8 hours per day, the maintenance interval should be adapted according
to requirements.
EN - 68
Health risk through inhalation of harmful welding fumes and dust
The welding process produces fumes with harmful dust particles which can settle on the
surface and get into the ambient air. They can damage the respiratory system when
inhaled.
► Check and wear your personal protective equipment.
► Only use the device in rooms which are sufficiently ventilated.
► Make sure that all the seals on the device are free of dirt.
► After cleaning and maintenance work check all screwed joints for a tight fit, leaks,
chafing points. Tighten any loosened screwed joints. Correct any faults found
immediately.
► Remove dust deposits in the surrounding area immediately using an industrial
vacuum cleaner of dust class H or a damp cloth.
Electric shock due to damaged or improperly installed cable
The use of damaged or improperly installed cables may result in a potentially fatal
electric shock.
► Check all live cables and connections for proper installation and damage.
► Have any damaged, deformed, or worn parts replaced by a qualified electrician
only.
Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can
start running unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.