Possibilities for a Temperature
a.) with temperature monito-
ring in the motor
Outflow
Inflow
Inflow
Outflow
b.) Temperature control without
temperature monitoring in the
26
There are two possibilities for a temperature control:
Control
a.) with temperature monitoring in the motor
b.) without temperature monitoring in the motor
In this case inverter and motor possess independent cooling circuits. Two program-
mable outputs of the control card are required for a control of the valve. (see the
following fig.).
Valve
Valve
In this case the motor is without temperature monitoring. The motor can be perma-
nently supplied with coolant or the motor can be integrated in the cooling circuit of
motor
the inverter.