Parameter
Power supply voltage range
Radio protocol
Radio frequency band
Max. transmitting power
Range
Supported device types
Leds channel current
Internal power consumption (stady state)
Internal power consumption (active state)
Overcurrent protection
Operating temperature
For installation in boxes
Dimensions (Height × Width × Depth)
Ambient humidity
Ingress Protection class
Compliance with EU directives
Note
• The maximum load rating is 0.3 A per channel, which means a maximum of 70 W for a load with Power Factor = 1 at 230 VAC.
• You can connect both channels of DoubleDimmer-Control with a wire for the device to work as if it had a single channel with a maximum load
rating of 0.6 A, which means a maximum of 140 W for a load with power factor = 1 at 230 VAC. Parameter 202 needs to be set to 1 - Outputs
connected.
4
INSTALLATION
4.1 - Safety notes
Danger of electrocution!
• DoubleDimmer-Control is designed to operate within a residential electrical installation. Faulty connection or improper use can result in a fire or
electric shock.
• All work on the device needs to be carried out by a qualified, licensed electrician, in accordance with national regulations.
• Even when the device is turned off, voltage may be present at its terminals. Any maintenance involving changes to wiring, to the configuration
of connections, or the load must always be performed with the fuse disabled.
• Connecting the device in a manner inconsistent with the manual can cause risk to health, life, or property.
Connect DoubleDimmer-Control in accordance with the following rules:
• Connect only in accordance with one of the diagrams below.
• The device should be installed in a wall switch box that complies with relevant national safety standards and has a minimum depth of 60 mm.
• Electrical switches used in the installation need to comply with applicable safety standards.
• Wires used to connect the control switch shouldn't exceed 100 m in length.
Value
220–240 VAC 50/60 Hz
Z-Wave (800 series chip)
EU: 868.4 MHz, 869.85 MHz
AH: 919.8 MHz, 921.4 MHz
+6dBm
• Up to 100 m outdoors
• Up to 30 m indoors
Depending on the terrain and building structure
• 220–240 V dimmable and non-dimmable LED loads (bulbs)
• 12–24 V LED or halogens with dimmable electronic transformers
• Dimmable LED drivers (for example, in LED strips)
0.3 A
Less than 500 mW
Less than 1 W
Each channel
0–40ºC
Ø = 50 mm, dept ≥ 60 mm
45 x 37 x 20 mm
Up to 95% without condensation and agressive gases
IP20
RoHS 2011/65/EU, 2015/863/EU, and RED 2014/53/EU