- Screw the suction hose with filter (not included)
onto the water connection of the unit.
- Hang the filter in the container.
- Vent the unit before operation.
- Unscrew the high-pressure line at the high-
pressure outlet of the unit.
- Switch on the unit and let it run until water free of
bubbles emerges at the high-pressure outlet.
- Switch off the unit and screw on the high-
pressure hose again.
Failure to comply with the above conditions causes
serious mechanical damage to the pump and the
loss of warranty cover.
> ELECTRICITY SUPPLY
- The appliance's electrical connection must
comply with the IEC 60364-1 standard.
IMPORTANT: Before connecting the appliance,
make sure that the nameplate data are the
same as those of the electrical mains and that
the socket is protected by a differential security
breaker with tripping sensitivity below 0.03 A - 30
ms.
- If the appliance's plug is not compatible with the
socket, have the socket replaced with another of
suitable type by professionally qualified staff.
- Never use the appliance in ambient temperatures
below 0° C if it is equipped with a PVC (H VV-F)
cable.
WARNING:
26
•
Improper extension cables can
be dangerous. If an extension cord is used, it must
be suitable for outdoor use, and the connection
must be kept dry and clear of the ground. It is
recommended that this be done using a cable
reel that holds the plug at least 60 mm from the
ground.
WARNING:
27
•
If an extension cord is used,
the plug and socket must be of watertight
construction.
Information for supply may also be obtained
from the plug manufacturer.
<16 A
<20 m
ø 1,5 mm
14 AWG
20 m - 50 m ø 2,5 mm
12 AWG
<25 A
ø 2,5 mm
2
2
12 AWG
ø 4,0 mm
2
2
10 AWG
> PLUG
HOW TO CONNECT THE CORD TO A U.K. PLUG:
IMPORTANT The wires in the mains lead are
coloured in accordance with the following code:
Blue
Neutral
Brown Live
Yellow/Green Earth
Please read the instructions given below before
connecting the cord to a plug. If in doubt please
consult a qualified electrician. As the colours of the
wires in the mains lead of this appliance may not
correspond with the coloured markings identifying
the terminals in your plug, proceed as follows: The
wires that is coloured Brown must be connected
to the terminal which is marked with the letter L or
coloured Red. The wire that is coloured Blue must
be connected to the terminal wich is marked with
the letter N or coloured Black. Safety points for
rewireable or moulded plug: The mains lead of this
appliance may be already fitted with a BS1363 13A
plug.
- If your socket outlet is not suitable for the plug,
then the plug must be removed (cut off if it is a
moulded on plug), the flexible cord insulation
should be stripped back as appropriate and a
suitable 3 pin plug fitted.
WARNING:
•
Dispose of a plug that has been
cut from the power supply cord, as such a plug
is hazardous if inserted in a live 13A socket outlet
elsewhere in the house. - Should the fuse need
to be replaced an ASTA marked fuse, approved to
BS1362, of the same rating must be used. - Always
replace the fuse cover after fitting a fuse. The
plug must NOT be used if the cover is omitted
EN