Herunterladen Inhalt Inhalt Diese Seite drucken

Electricity Supply - Lavorwash Rio-R Bedienungsanleitung

Heißwasser-hochdruckreiniger
Vorschau ausblenden Andere Handbücher für RIO-R:
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
EN
mains if the water mains is separated by a back-
flow preventer. Make sure that the hose is at least
Ø 13mm-1/2 inch and that it is reinforced, 5-25 m.
WARNING:
backflow preventers is considered to be nonpo-
table.
IMPORTANT:
should be used for intake. The delivery of the wa-
ter intake tap should be equal to the double of
the maximum pump range.
- Minimum delivery rate: 15 l/min.
- Maximum intake water temperature: 40°C
- Max inlet water pressure: 1 Mpa
Place the cleaner as close to the water supply sys-
tem as possible.
Failure to comply with the above conditions causes
serious mechanical damage to the pump and the
loss of warranty cover.
Water supply from the water main
- Connect a supply hose (not included) to the wa-
ter inlet of the unit and to the water supply.
- Open the water supply.
Water supply from an open container
- Unscrew the coupling part for the water inlet.
- Screw the suction hose with filter (not included)
onto the water connection of the unit.
- Hang the filter in the container.
- Vent the unit before operation.
- Unscrew the high-pressure line at the high-pres-
sure outlet of the unit.
- Switch on the unit and let it run until water free of
bubbles emerges at the high-pressure outlet.
- Switch off the unit and screw on the high-pres-
sure hose again.
> ELECTRICITY SUPPLY
- The appliance's electrical connection must com-
ply with the IEC 60364-1 standard.
IMPORTANT:
pliance, make sure that the nameplate data are
the same as those of the electrical mains and that
the socket is protected by a differential security
breaker with tripping sensitivity below 0.03 A - 30
ms.
- If the appliance's plug is not compatible with the
socket, have the socket replaced with another of
suitable type by professionally qualified staff.
- Never use the appliance in ambient temperatures
20
Water that has flown through
Only clean or filtered water
Before connecting the ap-
below 0° C if it is equipped with a PVC (H VV-F)
cable.
- No actions needed for adjusting machines mar-
ked with dual voltage and frequency.
WARNING:
•26
can be dangerous. If an extension cord is used,
it must be suitable for outdoor use, and the con-
nection must be kept dry and clear of the ground.
It is recommended that this be done using a cable
reel that holds the plug at least 60 mm from the
ground.
WARNING:
•27
the plug and socket must be of watertight con-
struction.
Information for supply may also be obtained
from the plug manufacturer.
<16 A
<20 m
ø 1,5 mm
2
20 m - 50 m ø 2,5 mm
2
> PLUG
How to connect the cord to a u.k. plug:
IMPORTANT
The wires in the mains lead are
coloured in accordance with the following code:
Blue
Neutral
Brown Live
Yellow/GreenEarth
Improper extension cables
If an extension cord is used,
<25 A
- 14 AWG ø 2,5 mm
- 12 AWG
2
- 12 AWG ø 4,0 mm
- 10 AWG
2
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rio-r proKappa a-rXtr-r

Inhaltsverzeichnis