Malfunctions
Measures to rectify malfunctions are listed below.
If these actions do not produce the desired result,
contact Truma Service.
11.1 Unstable supply voltage
If the air conditioning system is started on a stable
power supply, the compressor switches on after
3 minutes.
If the power supply is not sufficiently stable (unstable
voltage / frequency), the device switches off during
operation.
Check the following possible sources of error:
Check the mains power source.
Check whether the power inverter/generator is one
that fulfils the parameters recommended in the
operating instructions.
If other appliances are already connected to the
mains (e.g. microwave), switch them off and try
again.
Check the mains power cable; keep it as short as
possible.
When operating with a power inverter, check the
charge status of the battery.
Once a stable power supply has been restored, the
device restarts automatically without having to be
switched on manually.
11.2 Troubleshooting
Error
Appliance not
cooling
Device not heating
Device cooling /
heating
inadequately or
not at all
Moisture on
underside of air
distributor
40091-01234 ∙ 00 ∙ 10/2024
Cause / remedy
Thawing process in
progress
Remote control
temperature setting
reached or too high
Thawing process in
progress (outside
temperature between 4 °C
– 7 °C)
Outside temperature below
4 °C
Panels dirty, clean panels
External air routes soiled /
blocked
Close windows and doors
and select high fan level
Error
Water dripping out of
air distributor
Remote control
not working
Appliance not
reacting to remote
control commands
Red LED on the
button of the air
distributor flashing
Device switches
itself off during
operation
White LED on the
button of the air
distributor flashing
If these actions do not remedy the problem, please
contact Truma Service.
Malfunctions
Cause / remedy
Condensation trap on
external unit blocked
Seal between appliance
and roof not intact (e.g.
faulty seal)
System at too much of an
angle
Check the batteries in the
remote control and replace
if necessary
Remote control out of
range
Remote control not paired
with air conditioning
system
There is an error in the
control system.
Switch the air conditioning
system off, wait for a short
time and then switch
it on again. If the red
LED remains lit, contact
Truma Service. Make a note
of the error code displayed
on the control panel.
It may still be possible to
continue operation in air
circulation mode.
Check power supply
Bluetooth pairing
not possible. Delete
superfluous Truma apps
and repeat pairing.
EN