Aventa compact 2.G / Aventa compact plus 2.G
14
Technical data
Determined in accordance with EN 14511 or
Truma test conditions
Aventa
compact
Operating voltage
Rated current con-
3.3 A
sumption, cooling
Rated current con-
1.6 A
sumption, heating
Nominal cooling
1600 W
capacity
Nominal heating
capacity (heat
1200 W
pump)
Air flow volume
330 m³/h
Ambient tem-
16 °C – 45 °C (cooling mode)
perature during
4 °C – 30 °C (heating mode)
operation
Maximum angle
8 % or 4.5°
during operation
Weight
20.5 kg
Dimensions
(L x W x H)
Air distributor
dimensions
(L x W x H)
Refrigerant
Refrigerant filling
quantity
Global Warming Po-
tential (GWP)
CO
equivalent
2
Subject to technical changes.
Download general operating permit (ABE):
www.truma.com/de/service/download-center/
40091-01234 ∙ 00 ∙ 10/2024
Aventa
compact plus
230 V – 240 V AC, 50 Hz
4.9 A
2.1 A
2070 W
1500 W
350 m³/h
21.5 kg
786 x 577 x 245 mm
550 x 497 x 45 mm
R 290 (propane)
124 g
132 g
3
372 g
14.1 Dimensions (in mm)
Fig. 18
Fig. 19
Technical data
786
113
550
EN
35