• Rinse the device with clear water
until the lines are free of cleaning
agent.
2. Release the switch lever (17).
3. Move the On/Off switch (32) to the
position "0" (OFF).
4. Close the tap.
5. Press the switch lever (17) on the trig-
ger gun (1) until the pressure has been
released.
6. Pull out the plug. Wind the mains con-
nection cable (10) on the holder (11).
7. Disconnect the device from the water
supply.
Cleaning, maintenance
and storage
WARNING! Electric shock! Risk of in-
jury due to unintentional start-up. Protect
yourself when performing maintenance or
cleaning work. Switch off the device and
disconnect the mains plug from the socket.
You should have any repair and mainten-
ance work that is not described in these
instructions carried out by our Service
Centre. Only use original replacement
parts.
Cleaning
NOTICE! Risk of damage! Improper
cleaning can damage the device. Never
spray down the device with water. Do not
clean the device under running water. Do
not use any abrasive cleaning agents or
solvents.
Always keep the device clean.
Cleaning after operation
1. Move the On/Off switch (32) to the
position "0" (OFF).
2. Pull out the plug.
3. Keep the ventilation slits clean and free
of objects.
4. Clean the device with a soft brush or a
slightly damp cloth.
Cleaning the standard vario-
nozzle
In rare cases, the standard vario-nozzle
may become clogged by foreign bodies.
1. Remove the standard vario-nozzle ().
2. Remove the foreign body from the front
using the nozzle cleaning needle (6).
3. Rinse the standard vario-nozzle with
water from the front to remove the for-
eign body.
Cleaning the filter insert in the wa-
ter connection
1. Remove the coupling (29) from the wa-
ter connection (28).
2. Remove the filter insert (30) from the
water connection.
3. Clean the filter insert under running
water.
4. Fit the filter insert (30) and coupling
(29) in reverse order.
Replacing the batteries
Replace the batteries if the LC display (15)
is not displaying anything.
Power tools required
• Phillips screwdriver (not included)
Replacing the batteries
1. Remove the screw from the battery
compartment cover (16).
2. Remove the cover of the battery com-
partment.
3. Replace the batteries (35) in the bat-
tery compartment with new batteries.
Pay attention to the correct polarity
when inserting the batteries in the bat-
tery compartment.
4. Press the switch lever (17) on the trig-
ger gun (1).
The LC display shows the selected pres-
sure. If the LC display is not displaying
GB
MT
39