IBPM
DPT-6000 (DPT-6003 & DPT-6009)
DPT-9000 / Xtrans
Overview (p. 3–9)
Blood
Column Row
Designation
sampling
-, CLC, SWAN A–F, X,Y
transducer types
IV
DPT-6003 or
NBSS, NBSS
,
XL
A–F
ABSS, ABSS
XL
-, CLC, SWAN A–F, X,Y
IV
Flush system
NBSS, NBSS
,
XL
A–F
ABSS, ABSS
XL
-, CLC, SWAN A–F, X,Y
IV
Electrical contacts
NBSS, NBSS
,
XL
A–F
ABSS, ABSS
XL
-, CLC, SWAN A–F, X,Y
3-way zeroing
IV
NBSS, NBSS
,
XL
A–F
ABSS, ABSS
XL
transducer types
All
F
IV
DPT-6009 or
Flush system
All
F
IV
Electrical contacts
3-way zeroing
All
B
V
2-way stopcock
3-way stopcock
All
B
V
4-way stopcock
(Selectable
Eliminator of
All
C
V
Resonance
Overshoot)
damping stopcock
VI–
CLC (Classic
CLC
A–Y
VII
Confi guration)
3-way stopcock
4-way stopcock
CLC
A–Y
VII
ArterioGuard
(4-way stopcock)
SWAN Switch
VI–
SWAN
A–Y
VII
Adaptor Needle-
VI–
(Needle-free
NBSS
A–F
VII
Blood Sampling
VI
Reservoir (2 ml)
NBSS
A–F
SWAN Switch
VII
(Swabable Adaptor
Needle-free)
VI–
(Needle-free
NBSS
A–F
XL
VII
Blood Sampling
20.1028.00/2022-10
(DPT-9003 & DPT-9009)
®
Part of
Pressure
• Conversion of a physical pressure (blood pressure) into
-
an electrical signal
DPT-9003
• Rapid fl ushing and continuous fl ushing
(Xtrans
)
®
• Rapid fl ushing for fi lling and the removal or air pockets
and/or blood residue
• Continuous fl ushing (3 ml/h at 300 mmHg) to prevent the
patient access port from becoming clogged
DPT-6003,
• Connecting the pressure transducer to an electrical acces-
DPT-9003
sory for signal transmission
• Zero calibration of the pressure transducer
stopcock
• Setting of three possible fl ow directions (180°)
Pressure
• Conversion of a physical pressure (blood pressure) into
-
an electrical signal
DPT-9009
• Rapid fl ushing and continuous fl ushing
(Xtrans
)
®
• Rapid fl ushing for fi lling and the removal or air pockets
and/or blood residue
• Continuous fl ushing (30 ml/h at 300 mmHg) to prevent the
patient access port from becoming clogged
DPT-6009,
DPT-9009
• Connecting the pressure transducer to an electrical acces-
sory for signal transmission
• Zero calibration of the pressure transducer
stopcock
• Setting of three possible fl ow directions (180°)
Temporary
• Transmission of the physical pressure (blood pressure)
pressure
-
to a pressure transducer
monitoring
• Alternating between two pressure channels
Setting of two possible fl ow directions (90°)
Setting of three possible fl ow directions (180°)
Temporary
pressure
monitoring
Setting of four possible fl ow directions (360°)
S.E.R.O.
• Transmission of the physical pressure (blood pressure)
to a pressure transducer
-
• Switching an attenuator on and off to correct falsely
high/low measured values (overshoot)
• Setting of four possible fl ow directions (360°)
• Transmission of the physical pressure (blood pressure)
-
to a pressure transducer
• Blood sampling
• Blood sampling
• Setting of three possible fl ow directions (180°)
• Blood sampling
• Setting of four possible fl ow directions (360°)
CLC
• Blood sampling
• Check valve protects against intra-arterial injections initiated
®
by mistake
• Setting of four possible fl ow directions (360°)
• Transmission of the physical pressure (blood pressure)
(Swabable
to a pressure transducer
-
• Hygienically closed blood sampling
free)
• Setting of four possible fl ow directions (360°)
• Transmission of the physical pressure (blood pressure)
NBSS
to a pressure transducer
-
• Hygienically closed blood sampling
• Drawing, short-term storage (duration of a blood
System)
sampling process) and return of mixed blood
• Drawing, short-term storage (duration of a blood sampling
process) and return of mixed blood (2 ml)
• Protection against the ingress of pathogens
NBSS
• Hygienically closed blood sampling
• Setting of four possible fl ow directions (360°)
• Transmission of the physical pressure (blood pressure)
NBSS
XL
to a pressure transducer
-
• Hygienically closed blood sampling
• Drawing, short-term storage (duration of a blood
System)
sampling process) and return of mixed blood
Component
Main functional & operating features
Quantity
Note
1–4
-
1
-
1
-
1
-
1–2
-
1
-
1
-
1
-
Only in combination
with pressure monito-
1
ring sets with a single
pressure transducer
• 2-way stopcock with
or without a connec-
ted or enclosed pres-
sure monitoring line
1
• 3-way or 4-way stop-
cock with a connected
or enclosed pressure
monitoring line
1
-
1
-
ArterioGuard
only in
®
combination with a
1–3
(pulmonary)-arterial
set-up of a pressure
monitoring set
1–3
-
Only in combination
with a (pulmo-
1
nary)-arterial set-up
of a pressure monito-
ring set
1
-
1–3
-
Only in combination
with a (pulmo-
1
nary)-arterial set-up
of a pressure monito-
ring set
43