Overview (p. 3–9)
Blood
Column Row
sampling
All
-
All
A
All
A
All
B–D
B–D
All
B–D
D
All
E
All
E
All
F
-, CLC, SWAN
Y
-, CLC, SWAN
Y
42
Designation
Part of
Sterile packaging
-
(sterile barrier
-
system)
AeroGuard
®
(filling and
I–III
-
irrigation system
with fi lter system)
Drip chamber
macro
(vented or non-
vented)
Drip chamber micro
I
(vented or non-
vented)
AeroGuard
Spike
(vented or non-
vented)
I
Roller clamp
II
Filter system
Filling and
I–III
-
irrigation system
Drip chamber
macro
(vented or non-
vented)
Drip chamber micro
I
(vented or non-
vented)
Spike
Filling and
(vented or non-
irrigation
vented)
system
1
Roller clamp
Sliding clamp
III
Free fi lling outfl ow
with a male Luer
connector
ADD fi lling and
I–III
irrigation system
-
(basic)
Drip chamber
macro (vented or
non-vented)
I
Drip chamber
ADD fi lling
micro (vented or
and irrigation
non-vented)
system (basic)
Spike (vented or
non-vented)
I
Roller clamp
III
4-way stopcock
Filling line with
II–III
female Luer
-
connector
ADD fi lling and
II–III
irrigation system
-
(addition)
ADD addition line
II
with a male Luer
ADD fi lling
connector
and irrigation
system
(addition)
III
4-way stopcock
Component
Main functional & operating features
• Protection against the ingress of pathogens
• Maintaining the sterile condition
• Identifi ability and traceability
• Easy and residue-free opening
• Connecting the pressure monitoring set to a saline bag
for fi lling and rinsing the pressure monitoring set with
saline solution
• Particle fi ltration and air separation
• Connection to a saline bag (vented or non-vented)
• Setting the liquid level
• Flow control (20 drops per millilitre)
• Particle fi ltration (15 µm)
• Connection to a saline bag (vented or non-vented)
• Setting the liquid level
• Flow control (60 drops per millilitre)
• Particle fi ltration (15 µm)
®
• Connection to a saline bag (vented or non-vented)
• Flow control (opening and closing the fl ow channel)
• Particle fi ltration (1.2 µm)
• Elimination of air pockets
Connecting the pressure monitoring set to a saline bag
for fi lling and rinsing the pressure monitoring set with
saline solution
• Connection to a saline bag (vented or non-vented)
• Setting the liquid level
• Flow control (20 drops per millilitre)
• Particle fi ltration (15 µm)
• Connection to a saline bag (vented or non-vented)
• Setting the liquid level
• Flow control (60 drops per millilitre)
• Particle fi ltration (15 µm)
• Connection to a saline bag (vented or non-vented)
• Flow control (opening and closing the fl ow channel)
• Flow control (opening and closing the fl ow channel)
• Addition of a pressure transducer without a fi lling system or
fi lling line (X/IV – CLC & SWAN)
• Connecting the pressure monitoring set to a saline bag
for fi lling and rinsing the pressure monitoring set with
saline solution
• Connecting the pressure monitoring set to an ADD fi lling
system (extension) (Y/II – CLC & SWAN)
• Connection to a saline bag (vented or non-vented)
• Setting the liquid level
• Flow control (20 drops per millilitre)
• Particle fi ltration (15 µm)
• Connection to a saline bag (vented or non-vented)
• Setting the liquid level
• Flow control (60 drops per millilitre)
• Particle fi ltration (15 µm)
• Connection to a saline bag (vented or non-vented)
• Flow control (opening and closing the fl ow channel)
• Connection to an ADD addition line (Y/II – CLC & SWAN)
• Setting of four possible fl ow directions (360°)
Connecting the pressure monitoring set to a disposable
syringe for fi lling and rinsing the pressure monitoring set
with saline solution
Connecting the pressure monitoring set to an ADD fi lling
system (basic) (E/III) or an ADD fi lling system (addition)
(Y/II – CLC & SWAN) for fi lling and rinsing the pressure
monitoring set with saline solution
Connection to a 4-way stopcock of an ADD fi lling system
(basic) (E/III – CLC & SWAN) or an ADD fi lling system (addi-
tion) (Y/III – CLC & SWAN)
• Connection to an ADD addition line of an ADD fi lling system
(addition) (Y/III – CLC & SWAN)
• Setting of four possible fl ow directions (360°)
Quantity
Note
• A single sterile
barrier system is
labelled with the
symbol 21
1–2
• A double sterile
barrier system is
labelled with the
symbol 22
Only in combination
with pressure trans-
1
ducer types DPT-6003
or DPT-9003
1
-
1
-
1
-
Only in combination
with pressure trans-
1
ducer types DPT-6003
or DPT-9003
1
-
1
-
Only in combination
with pressure monito-
1–4
ring sets with two or
more fi lling cannulae
1–3
-
Only in combination
with pressure trans-
1
ducer types DPT-6003
or DPT-9003
1
-
1
-
1
-
Only in combination
with pressure trans-
1–2
ducer types DPT-6009
or DPT-9009
Only in combination
with pressure trans-
1
ducer types DPT-6003
or DPT-9003
1
-
1
-
CODAN pvb Critical Care GmbH