Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)
1. Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific information on the type,
the amount and the CO2 equivalent in tonnes of the fluorinated greenhouse gas(on some models), please refer to
the relevant labelon the unit itself.
Installation, service, maintenance and repair of this unit must be performed by a certified technician.
2.
3.
Product uninstallation and recycling must be performed by a certified technician.
WARNING for Using R290 Refrigerant
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the
•
manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames,
•
an operating gas appliance or an operatingelectric heater).
Do not pierce or burn.
•
Be aware that the refrigerants may not contain an odour.
•
Appliance should be installed, operated and stored in a room with a floor area according to the amount of
•
refrigerant to be charged. For specific information on the type of gas and the amount, please refer to the relevant
label on the unit itself.When there are di erences between the lable and the manual on the Min. room area
description, the description on label shall prevail.
For R290
amount of refrigerant (kg)
0.0836
≥
<
0.0836 and
0.1045
≥
<
0.1045 and
0.1254
≥
<
0.1254 and
0.1463
≥
<
0.1463 and
0.1672
≥
<
0.1672 and
0.1881
≥
Min. room area(m )
amount of refrigerant (kg)
4
<
0.1881 and
5
<
0.2090 and
6
<
0.2299 and
7
<
0.2508 and
8
<
0.2717 and
9
<
0.2926 and
Min. room area(m )
10
0.2090
≥
11
0.2299
≥
12
0.2508
≥
13
0.2717
≥
14
0.2926
≥
15
0.3040
≥