MAINTENANCE, SERVICING AND DISMANTLING
8.6
Conditions for switching on again
The following points must be observed before restarting after maintenance and servicing work:
• Unauthorised persons must be removed from the pump.
• The proper connection between the pump and the media lines must be checked.
• The media lines must be checked for leaks and damage.
• The power supply must be checked for damage and proper functioning.
• All operating fluids must be filled to the correct level.
• All protective devices must be present, functional and tested.
8.7
Spare parts
NOTICE
Material number
ZS1249244
ZS1249246
ZS1249249
ZS1249250
ZS1249251
Tab. 10 Spare parts
8.8
Temporary shutdown
The following steps must be observed during a temporary shutdown:
1.
Shutdown
2.
To switch off, the pump must be shut down and secured against being switched on again. In
addition, a warning sign must be attached to the mains disconnection device.
3.
All existing electrical equipment must be disconnected individually.
4.
Disconnection from the power supply
5.
A verifiably qualified electrician switches the motor free and disconnects it. After carrying out the 5
safety rules, non-qualified electricians may also carry out activities on the pump.
6.
After completion of the decommissioning, the activities under the item: „Recommissioning" must be
followed.
8.9
Cleaning
DANGER
34
|
www.elmorietschle.com © Gardner Denver Schopfheim GmbH
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Property damage due to wrong or defective spare parts!
Wrong or defective spare parts can cause malfunctions or blackout failure of the
machine.
¾ Only use original spare parts or parts approved by the manufacturer.
¾ The use of other parts may revoke liability or guarantee for any resulting
consequences.
Description
Vane kit VTR 61-81
Vane kit VTR 101 - 141
Filter cartridge vacuum side VTR 61 - 141
Filter cartridge pressure sideVTR 61 - 81
Filter cartridge pressure side VTR 101 - 141
Danger to life due to unexpected start-up.
Tel. 071 918 60 60, Mail: v-g@prematic.ch