MAINTENANCE, SERVICING AND DISMANTLING
2
If safety devices have to be dismantled or modified, they must be refitted, adjusted and tested imme-
diately after completion of the maintenance and servicing work and before the pump is started.
3
After this, a qualified electrician may carry out work on the pump, taking into account the 5 safety
rules.
Once the work has been completed, the pump may be put back into operation after a visual inspection.
8.3
Maintenance Intervals
The maintenance intervals are shown in the following overview:
Maintenance components
Fig. 8
Component
Rotary valve (1)
Intake filter (2)
C-separator (3)
Warehouse (4)
Housing
Pump fans
Clutch / spider
Safety and protecti-
ve equipment
General overhaul
Tab. 8 Maintenance intervals
28
|
www.elmorietschle.com © Gardner Denver Schopfheim GmbH
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
40 - 200 h
2000 h (min. 2x/1a)
check, clean
check, clean
clean
Check whether
complete and intact
Interval time
3000 h
measure, change
change
change
Relubricate
Relubricate
check, clean
check
8000 h (min. 1x/3a)
execute