Herunterladen Diese Seite drucken

Abicor Binzel EWR 2 Net MFC-Mode Originalbetriebsanleitung Seite 58

Gas-management-system
Vorschau ausblenden Andere Handbücher für EWR 2 Net MFC-Mode:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

14 Fluid plan
13.2 Commands/parameter – CANopen
Address
r/w
Description
0x1002
r
Status register
0x2108sub1
r
Temperature
0x2109sub1
r
Input voltage
0x6400sub1
r
Operating mode
0x6401sub1
r
Incoming pressure
0x6402sub1
r
Outgoing pressure
0x6403sub1
r
Flow
0x6200sub1
r/w
Basic flow
0x6200sub2
r/w
Stagnation pressure
14 Fluid plan
1 - 6 bar
EN - 26
Unit/explanation
Coded as Ethernet command "sys"
1/10 degrees Celsius
1/10 volts
0: Bypass, 1: Outlet pressure regulation, 2: volume flow regulation
1/10 bar
1/10 bar
1/10 l/min
1/10 l/min
1/10 bar
P
IN
IN
IN/OUT
Input/output
P P
Relative pressure sensor
IN, OUT
p
Differential pressure sensor
PV
Proportional solenoid valve
BI
Metering orifice
PV
p
BI
EWR 2 Net MFC Mode
P
OUT
OUT

Werbung

loading

Diese Anleitung auch für:

Ewr 2Ewr 2 net