5 Quick installation
5 Quick installation
Mount the device.
1
 6 Assembly on page EN-12
Note the date of the next service on the service sticker (date of commissioning or service plus one year).
2
 2.3 Warning and notice signs on page EN-5
Connect the device.
3
 7.1 Establishing connections on page EN-12
Switch on the device.
4
 8.1 Switching on the device on page EN-14
Wait for the self diagnosis function to start.
5
 11 Faults and troubleshooting on page EN-20
Make the settings as needed and configure the basic flow, set pressure, and gas type.
6
 4.2 Authorization levels/password on page EN-8
 8.5 Submenu 1 Parameter on page EN-16
The device is then ready for operation.
6 Assembly
NOTICE
Restricted functioning and malfunction of the device due to improper mounting
If the device is mounted at too great a distance from the solenoid valve or together with other gas
management systems, the regulation function of the device will be restricted and will not function
properly.
► Mount the device in the front of the solenoid valve (as close to it as possible) in the wire feeder and
► Remove any additional gas management systems within the gas line.
7 Commissioning
► Note the date of the next service on the service sticker (date of commissioning or service plus one year).
 2.3 Warning and notice signs on page EN-5
7.1 Establishing connections
 Fig. 3 Control elements and connections on page EN-9
Close off the gas supply.
1
Use a hose cutter to cut the insulating hose at a suitable point and connect it to the gas supply line (K)
2
and gas discharge line (F).
Establish Ethernet (G) and CANopen (H) connections.
3
 7.2 Setting the communication interfaces on page EN-12
Turn on gas supply completely and check for leaks. If necessary, turn off the gas supply and note
4
the instructions in the following chapter:
7.2 Setting the communication interfaces
The serial interface (connection for the jack plug) is used for communication with the device. The Ethernet
interface can be used as an alternative communication interface.
EN - 12
in the direction of gas.
EWR 2 Net MFC Mode
► Mount the device at a suitable location using
fastening screws (not included in the scope of
delivery).