Herunterladen Diese Seite drucken

Abicor Binzel EWR 2 Net MFC-Mode Originalbetriebsanleitung Seite 55

Gas-management-system
Vorschau ausblenden Andere Handbücher für EWR 2 Net MFC-Mode:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EWR 2 Net MFC Mode
Tab. 12
Commands/parameters – serial and Ethernet
Command r/w Authorization Reply
sys
r
r-all
bsz x
r
r-all
Settings
lang
r/w
r-all
w-Setter
ga x
r/w
r-all
w-Setter
gf x y
r/w
r-all
w-Setter
gn x y
r/w
r-all
w-Setter
gs x y
r/w
r-all
w-Setter
bl x
r/w
r-all
w-Setter
Description
sys xxx
Current system status (bitwise coded) hexadecimal:
as 32-bit value
Error from the application:
Bit0 = calibration data for check sum error
Bit1 = calibration data error
Bit2 = settings for check sum error
Bit3 = sensor system error
Bit4 = input pressure too low error
Bit5 = input pressure too high error
Bit7 = leakage error
Bit8 = input voltage too low error
Bit9 = input voltage too high error
Bit10 = temperature error
Bit11 = reserved
Bit12 = flow limit error
All other bits should be ignored.
bsz x yyyy
Operating hours counter (all times in sec.)
x = counter type:
0: Number of power cycles (on/off switch cycles)
1: Time in undervoltage (< 24 V − 10%)
2: Time in normal voltage
3: Time in overvoltage (> 24 V + 10%)
4: Time with flow regulation active
5: Time with pressure regulation active
6: Gas consumption amount in L
10..19: Error memory 0..9
 11 on page EN-20
20..29: Time stamp for error number 0..9
lang x
Setting for display menu language.
0 English
1 German
2 Spanish
ga x
Selection of gas type to be used.
x = index of current gas
0...9 set gas
gf x y
Configuring gas factors for the gas type (ga).
x = gas index
y = factor in 1/10% (1000 = 1.0)
gn x y
Configuring the gas name.
x = gas index
y = gas name as string (max. 10 characters)
gs x y
Flag for displaying the gas in the display
x = gas index
y = 1: gas is displayed and can be selected;
0: gas is not displayed (and cannot be selected)
bl x
Backlight mode
x = 0 (off after approx. 5 min)
x = 1 (continuously on)
13 Description of interface
Value range
0x0000000
Long 4Byte 
0...0xFFFFFFFF
Seconds
resolution up to
136.2 years
x = 0 to 2
x = 0 to 9
x = 0 to 9
y = 500 to 1500
x = 0 to 9
y = string
x = 0 to 9
y = 0 or 1
x = 0 or 1