EWR 2 Net MFC Mode
8.3 Reading actual values
8.3.1 Gas volume flow regulation
Gas volume flow regulation is used to configure the basic flow.
8.3.2 Outlet pressure regulation
The set pressure is the pressure that the system sets between the device output and the solenoid valve in the
wire feeder when welding is not in progress and the solenoid valve in the wire feeder is closed.
8.4 Main menu
This display appears after the diagnosis run is finished with no errors. The basic
flow can be set with the "Setter" or "Service" authorization.
 4.2 Authorization levels/password on page EN-8
To set the basic flow, press the <▲▼> and <◄ ►> arrow buttons.
1
To save the entry, press the <OK> button, or to discard the last change,
2
press the <On/Bypass> button.
► To switch between the actual value displays, press the <◄ ►> arrow buttons.
These actual value displays are for informational purposes only. Values cannot
be changed.
► To switch between the actual value displays, press the <◄ ►> arrow buttons.
These actual value displays are for informational purposes only. Values cannot
be changed.
To open the main menu, press the <OK> button.
1
The following main menus are available:
To switch between the main menus, press the <◄ ►> arrow buttons.
2
To select a main menu, press the <OK> button.
3
To return to the main menu, press the <▲> arrow button or the <On/Bypass>
4
button.
8 Operation
EN - 15