Gas-management-system
Vorschau ausblenden Andere Handbücher für EWR 2 Net MFC-Mode:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EWR 2 Net MFC Mode
4.3 Control elements and connections
Fig. 3
A Connection for jack plug
B <On/Bypass> button/
<ESC> button
C LED status indication
D Arrow buttons (4×)
Tab. 2
Pos. Name
(B)
(C)
(D)
(E)
(L)
Control elements and connections
E <OK> button
F Gas discharge line connection
(connecting piece 6 mm)
G Ethernet connection
H CANopen connection
A
B
C
L
K
Control elements
Function
<On/Bypass>
Pressing the <On/Bypass> button for a minimum of 2 seconds switches the
button/
regulation function on or off. If the <On/Bypass> button is pressed
only briefly, it closes the menu without saving (similar to the ESC button).
<ESC> button
LED status indication
The following displays can occur:
LED illuminates green:
— Device is switched on
— Shielding gas is regulated
LED illuminates red:
— Regulation function is switched off
— "Bypass" appears in the display
— Shielding gas is not regulated
LED illuminates alternating green and orange:
— Device is switched on
— Error message, fault is present
LED illuminates alternating red and orange:
— Regulation function is switched off
— Error message, fault is present
LED illuminates orange:
— Device is not ready for use
— Erroneous calibration data
— Have the device recalibrated by an ABICOR BINZEL service technician
 11 Faults and troubleshooting on page EN-20
Arrow buttons
Use the arrow buttons <▲▼> to change the settings (values) in the menu
options. The <▲> button is also the Back button at the superior menu level.
The arrow buttons <◄ ►> can be used to switch between different actual
value displays and between menu items within the current menu level.
<OK> button
Use this button to select a menu item and confirm an entry.
Display
The display shows target and actual values, parameters, and error
conditions. The display's background lighting switches off automatically
after 5 minutes. The background lighting can be regulated manually as of
firmware version A.01.03.00.
 8.8 Submenu 4 Settings on page EN-18
4 Product description
I Measurement shunt connection
J Power IN connection
K Gas supply line connection
(connecting piece 6 mm)
L Display
D
J
I
H
G
F
E
EN - 9