EWR 2 Net MFC Mode
The device restarts if settings/values are changed in the following submenus.
8.9 Bypass
To use the bypass function, the gas and power supply must remain connected. During a bypass, the device
does not regulate the gas flow rate and the regulation function is switched off. Values can be read on the
device and recorded in combination with the service software.
9 Decommissioning
Close the gas supply.
1
Disconnect the power supply.
2
To open the submenus, press the <OK> button.
1
The following submenus are available:
To switch between the submenu items, press the <◄ ►> arrow buttons.
2
To select a submenu, press the <OK> button.
3
To select the required settings/values, press the <▲▼> arrow buttons.
4
To save the setting and go to the previously selected submenu item, press
5
the <OK> button.
To return to the main menu, press the <▲> arrow button twice or the
6
<On/Bypass> button twice.
The text is displayed on the screen if the netmask values are invalid.
To select the required settings/values, press the <◄ ►> and <▲▼> arrow
1
buttons.
To save the settings, select the <OK> button. The device restarts.
2
Submenu <7 Netmask> is displayed automatically after three seconds.
Values can be changed here.
► To switch the device to bypass, press and hold the <On/Bypass> button for
approx. 2 seconds.
The gas volume flow and input pressure are displayed.
The LED status indicator illuminates red.
9 Decommissioning
EN - 19