SOLARFOCUS vamp air K 08 Handbuch Seite 28

Vorschau ausblenden Andere Handbücher für vamp air K 08:

Werbung

Aussenfreigabetemperatur
Zeitverzögerung Anf.
min. Einschaltdauer
Periodendauer
Leistung Elektroheizstab
Kompensation Leistungsdefizit
Software-Version ab V 20.030
vampair Revison
4 bis 5
RCC-Indoor SW
bis 5AE
Heating
Max. compressor speed
Max. Comp Speed > -5°C AT
Superheat set point
Startup SH Setpoint Inc. at heating
startup
Start-up duration
Start-up opening
Start-up speed duration
Start-up speed
Control Mode (EXV)
Heating EXV Kp
Heating EXV Ki
Heating EXV Kd
Startup SH Setpoint Inc. at start after
defrost
Startup SH Setpoint Inc. timout
Startup SH Setpoint Inc. speed limit
Startup SH Setpoint Inc. speed duration
EVI - valve
Superheat set point
Start-up duration
Start-up opening
Control Mode (EXV)
EVI EXV Kp
EVI EXV Ki
EVI EXV Kd
Cooling
Superheat set point
Startup SH Setpoint Inc. at cooling
startup
Start-up duration
Start-up opening
Start-up speed duration
Start-up speed
Control Mode (EXV)
Cooling EXV Kp
Cooling EXV Ki
Cooling EXV Kd
Underrange time
Defrost
Start-up duration
Start-up opening
Start-up speed duration
Start-up speed
Interval
Duration
End temperature
Delta threshold
Delta absolute threshold
Slow down cond. temp.
Slow down speed
Comp. stop delay before defrost
Max. compressor speed
Min. compressor speed
System parameter
Compressor model
Suction pressure sensor type
Discharge pressure sensor type
Intermediate pressure sensor type
28
-5
°C
60
Min.
10
%
30
Min.
9
kW
80
%
7000
rpm
7000
rpm
5
K
0
K
10
s
10
%
500
s
3000
rpm
0
1
0,01
1/s
1,5
s
2
K
80
s
3000
rpm
30
s
7
K
10
s
10
%
0
0,3
0,008
1/s
2
s
8
K
0
K
5
s
10
%
300
s
3000
rpm
0
1
0,04
1/s
1,5
s
15
Min.
5
s
0
%
5
s
3000
rpm
320
Min.
25
Min.
25
°C
3
K
5,7
K
5
°C
3000
rpm
0
s
5000
rpm
1800
rpm
vampair K10 3~
18
bar
50
bar
30
bar
Stator heater
Accessory power initial value
Compressor current protection
FREMAR frequency band
FREMAR frequency 1
FREMAR frequency 2
FREMAR frequency 3
min Compressor Speed
4-way switching speed
4-way switching delta pres.
max. power DHWT charg.
Max. forward temp.
Demand Offset
Forward temp-offset EVU-Lock
Capacity input mode
Digital input 1
Digital input 2
Digital output 2
Digital output 3
Heatp. TimePeriode
Outside temp condition
Demand P-factor
Analog Demand
Pre-opening phase duration
Pre-opening pressure
Drive speed rate
Control speed rate
Comp. speed delta sensitivity
Comp. speed delta scaling
Valve scaling threshold
Valve scaling minimum
Fan
Control speed heating
Ctrl speed heating temp.
Fan Speed CoolingCap
Cooling Capacity
Control speed cooling
Ctrl speed cooling temp.
Fan Delay after defrost
Fan overrun time (@Standby)
Ambient-temp.release fan overrun
max. duration fan overrun
evap.temp offset end temp
Fan Speed overrun time
Primary circuit pump
Pump Typ
Anti-freeze temperature
Pump runon
Set-flow rate anti-freeze
Min. flow rate
Max. flow rate
Max. speed
Anti-freeze Pump intermittent
Spreizung Heizbetrieb
Spreizung TWS Ladung
Spreizung Kühlbetrieb
Alarm
Low superheat threshold
Low superheat delay
Low pressure threshold
Low pressure delay
High condensing pressure threshold
High condensing pressure delay
Alarm pause
Envelope alarm delay
MOP threshold
High superheat threshold
High superheat delay
Oil return
Oil return speed
Oil return threshold
Oil return duration
Oil return threshold duration
Elektroheizstab
15
W
150
50
A
0
rpm
0
rpm
0
rpm
0
rpm
1800
rpm
1200
rpm
2,5
bar
9,5
kW
75
°C
0
W
0
Modbus
EVU Lock
No function
Interface
Stator heater
100
Min.
-22
°C
75
%
1
E/A
5
s
4
bar
67
rpm/s
20
rpm/s
10
rpm/s
40
%
10
%
50
%
Min. / Max.
.
54 / 62
%
6,5 / -10
°C
44 / 55
%
2500 / 4600
W
44 / 62
%
20 / 37
°C
45
s
Ein
E/A
3
°C
30
min
-0,9
°C
52
%
Wilo iPWM1
2
°C
120
s
600
l/h
800
l/h
2100
l/h
100
%
Ein
2
K
4
K
5
K
3
°C
90
s
1,3
barg
30
s
44,4
barg
10
s
10
Min.
10
s
25
°C
30
K
10
s
3600
rpm
2800
rpm
300
s
1000
s
air
Fachhandbuch vamp