9. Specifications
Model
Current/power consumption
Supply voltage UB
Load
Settling time
Ingress protection (per EN/IEC 60529)
Unplugged state
Plugged-in state
Electrical protection
Vibration resistance
Shock resistance
Immunity
Intended use
1) Relative linearity error is specified in accordance with Directive VDI/VDE/DKD 2638 chapter 3.2.6.
2) Protocol in accordance with CiA
3) Other settling times possible on request.
®
®
CANopen
and CiA
are registered community trademarks of CAN
Operating instructions, models F5301, F53C1, F5308, F53C8, F53S8
F5308 and F53C8 with UL
Current output 4 ... 20 mA
2-wire: signal current
Current output 4 ... 20 mA,
3-wire: < 8 mA
Voltage output: < 8 mA
®
CANopen
: < 1 W
DC 9 ... 36 V for current output
DC 13 ... 36 V for voltage
output
DC 9 ... 36 V for CANopen
≤ (UB – 10 V) / 0.024 A
for current output
> 10 kΩ for voltage output
≤ 2 ms (within 10 ... 90 % F
IP66, IP67
IP68, IP69, IP69K
Reverse polarity protection, overvoltage and short-circuit
resistance
20 g, 100 h, 50...150 Hz (in accordance with DIN EN 60068-2-6)
In accordance with DIN EN 60068-2-27
In accordance with DIN EN 61326-1/DIN EN 61326-2-3
EMC-strengthened versions
Indoor and outdoor use, typically at altitudes of up to 2,500 m
[8,202.5 ft] above sea level.
®
®
301, device profile CiA
F53S8
Voltage output: < 8 mA per
channel
DC 10 ... 30 V
®
≤ (UB – 10 V) / 0.020 A
(channel 1)
≤ (UB – 7 V) / 0.020 A
(channel 2)
3)
)
nom
IP67
404, communication service LSS (CiA
®
in Automation e. V.
EN
®
305)