5. Commissioning, operation
5.4.5 Pin assignment for MIL connector
Abbreviations, definitions
Signal
Description
EN
UB
Voltage source for sensor
UB+
Sensor-supply voltage (+)
UB-
Sensor-supply voltage (-)
S+
Output signal (+)
S-
Output signal (-)
CH1
Channel 1
CH2
Channel 2
0V
0V-Potential
For models F5301, F53C1 with UL and F53C1 for Atex Ex ib and F5308, F53C8
with UL and F53C8 for Atex Ex ib
MIL connector - 1-channel
MIL-CA3102E 16S-1P-B
1-channel 4 ... 20 mA, 3-wire
Signal
Pin
UB+
A
C
0V/S-
S+
D
Shield
Cable gland
Cable colours are only valid when using the standard WIKA cable, e.g. order number: 79100531
22
Cable colour
Brown
Blue
Black
-
Operating instructions, models F5301, F53C1, F5308, F53C8, F53S8
Signal
Description
Ammeter
A
Voltmeter
V
+
Voltage source
-
Switch
Shield [grounding]
1-channel 4 ... 20 mA, 2-wire
Signal
Pin
UB+/S+
A
0V/S-
C
Cable gland
Shield
1-channel 0 ... 10 V, 3-wire
Signal
Pin
A
UB+
0V/S-
C
S+
D
Shield
Cable gland
Cable colour
Brown
Blue
-
Cable colour
Brown
Blue
Black
-