9. Specifications
9. Specifications
Model
Rated force F
EN
Rated force F
Relative linearity error d
Relative repeatability error in
unchanged mounting position b
Temperature effect on
characteristic value TK
zero signal TK
Force limit F
L
Breaking force F
Shear force influence d
(Signal with 100 % F
Rated displacement (typ.) s
Material of measuring device
Rated temperature B
Operating temperature B
Storage temperature B
Electrical connection
Output signal
(rated output) C
Current consumption
Supply voltage UB
28
kN
nom
lbf
nom
1)
lin
rg
c
0
B
Q
under 90°)
nom
nom
T, nom
T, G
T, S
nom
Operating instructions, models F5301, F53C1, F5308, F53C8, F53S8
F5301 and F53C1 with UL
5
10
20
30
1,124 2,248 4,496 6,744 11,240 15,737 22,481 44,962
±1 % F
nom
±0.2 % F
nom
0.2 % F
/10 K
nom
0.2 % F
/10 K
nom
150 % F
nom
300 % F
nom
±5 % F
nom
< 0.1 mm [<0.004 in]
Corrosion-resistant stainless steel, 1.4542, ultrasound-
tested 3.1 material
Version with 3.2 material available
-20 ... +80 °C [-4 ... +176 °F]
-30 ... +80 °C [-22 ... +176 °F]
-40 ... +85 °C [-40 ... +185 °F]
Circular connector M 12x1, 5-pin
®
CANopen
circular connector, M12 x 1, 5-pin
4 ... 20 mA, 2-wire
4 ... 20 mA, 3-wire
2 x 4 ... 20 mA, redundant
DC 0 ... 10 V, 3-wire
2 x DC 0 ... 10 V redundant
®
CANopen
Protocol in accordance with CiA
®
CiA
404, communication services LSS (CiA
configuration of the instrument address and baud rate
Sync/Async, Node/Lifeguarding, heartbeat; zero and span
±10 % adjustable via entries in the object directory
Current output 4 ... 20 mA, 2-wire: signal current
Current output 4 ... 20 mA, 3-wire: < 8 mA
Voltage output: < 8 mA
®
CANopen
: < 1 W
DC 9 ... 36 V for current output
DC 13 ... 36 V for voltage output
DC 9 ... 36 V for CANopen
50
70
100
®
301, device profile
®
305),
®
200
2)