Emerson AVENTICS PROFINET-IO Montageanleitung Seite 29

Buskoppler cms, b-design

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Pin
Signal
Housing
Table 28: Pin assignment of the outputs at output module 8x, 8DO_M8, socket
M8x1
Pin
Signal
1
Free
3
GND
4
4
Ox
3
1
Housing
Table 29: Pin assignment of inputs at input module 8x, 8DI_M12, socket M12x1
Pin
Signal
1
SENSOR+
2
I1, I3, I5 or I7 Sensor signal
1
2
3
SENSOR-
5
4
3
4
I0, I2, I4 or I6 Sensor signal
5
NC
Housing
Table 30: Pin assignment of inputs at input module 8x, 8DI_M8, socket M8x1
Pin
Signal
1
SENSOR+
3
SENSOR-
4
4
I0 ... I7
3
1
Housing
Table 31: Pin assignment of load supply at output module 8x, 8DO, M12x1, A-
coded
Pin
Signal
1
Free
2
Ox
2 1
3
GND
3 4
4
Table 32: Pin assignment of plug X10 (POWER), 7/8"
Pin
Signal
1
0 V UQ1
2
0 V U
3
4
2
3
FE
5
1
4
24 V U
5
24 V UQ1
Table 33: Pin assignment of plug X10 (POWER), M12, A-coded
Pin
Signal
1
U
L
2 1
2
U
Q1
3
OV
3 4
4
U
Q2
13 Disposal
Improper disposal will lead to pollution of the environment. Furthermore, the
materials can no longer be recycled.
Dispose of the product, the packaging and any escaping operating materials
u
in accordance with the applicable national regulations.
AVENTICS™ PROFINET-IO | R412015162-BAL-001-AF | English
Assignment
Lies on shield potential
Assignment
Not connected
GND reference of actuator
Output signal Ox (nominal voltage 24 V)
Lies on shield potential
Assignment
24 V sensor supply +
GND reference potential
Not connected
Lies on shield potential
Assignment
Sensor supply +
Reference potential
Sensor signal
Lies on shield potential
Assignment
GND reference for supply voltage 2
24 V supply voltage 1 for outputs O0 ... O3
GND reference for supply voltage 1
24 V supply voltage 2 for outputs O4 ... O7
Assignment
0 V for valve voltage
0 V for logic and inputs
L
Ground
24 V for logic and inputs
L
24 V for valve voltage
Assignment
Power supply of the bus coupler logic and
sensor supply of the digital input modules
First valve power supply
Ground for U
, U
and U
L
Q1
Q2
Second valve power supply
14 Troubleshooting
14.1 Procedure
Step 1: Check the system
In case of malfunctions, first check the system or the system part where the
u
product is installed. Check the following items:
• All connections
• Settings. See
g 15. Technical
Step 2: Check the product
1. Make sure the system or system part is not under pressure or voltage.
2. Check the product based on the fault patterns described below.
3. Perform troubleshooting using the information under "Remedy".
If the malfunction cannot be eliminated as described under "Remedy": Disas-
semble the product and return it. See
4. After the malfunction has been eliminated; Put the system or product back
into operation.
14.2 Malfunctions
Error
Possible cause
SREG
Internal communication is disturbed. Possible
causes:
• Internal processing error occurs
• Subordinate SPI communication fails
• Initialization of SREG fails
SPI
SPI communication fails. Possible causes:
• Internal SPI error occurs (communication dis-
turbed)
• SPI timeout occurs (communication inter-
rupted)
APPL
Detected configuration (connected I/O modules)
contains unknown IDs
SYSTEM
Internal system error occurs
INIT
Product does not start, self test fails
BF lights up
Bus error
red
Voltage diagnosis
Error
Possible cause
UQ1 / UQ2
No supply voltage present at
the valve. Possible cause:
• Undervoltage missing
• Voltage missing
• Short circuit
Short circuit messages disappear after the problem is corrected.
OPEN LOOP detection disappears only after the error is corrected and the next
switching of the valve coil.
15 Technical data
This section contains an excerpt of the most important technical data. Further
technical data can be found on the product page in the Emerson store.
General
Ambient temperature for storage
min. ... max.
Ambient temperature during operation
min. ... max.
data.
g 4.3 Returning the
product.
Remedy
• Set PN diagnosis
alarm System Error
• Set diagnosis LED
• Set PN diagnosis
alarm System Error
• Set diagnosis LED
• Set PN diagnosis
alarm System Error
• Set diagnosis LED
• Set PN diagnosis
alarm System Error
• Set diagnosis LED
Carry out Reset
establish physical con-
nection
Configure participants
Configure participants
correctly
Remedy
Check supply voltage
Specifications
-20 ... +70 °C
0 ... +50 °C without condensation
29