5.8.3 Cleaning the dry air filter
Change filter element:
If the filter element or sealing ring is damaged
Attention
After cleaning twice
If there are soot-containing deposits
If moist or oily
When engine performance reduces or
the colour of the exhaust gas changes
Never operate the engine without air filter element
Remove cover (1).
Carefully remove filter element (2).
B5399029.ai
B5399031.ai
– Check filter element (2) for cracks or other damage by holding
against the light or using a lamp.
1
B5399032.ai
B5399030.ai
3
2
Clean filter cover (1) and housing (3).
Replace filter element or clean appropriate.
If there is any dry pollution: Blow out the filter cartridge with dry
air under pressure (max. 5 bar) from the inside outwards, until
no more dust comes out.
Risk of eye injuries! – Wear safety goggles.
Danger
Care refit filter element (2).
Fit cover (1).
60
5. Maintenance
max. 5 bar
2
2
B5399033.ai