3.3.2 If the engine starts
1 – 2 min.
Adjust engine speed control lever (1) to idle position.
Allow the engine to warm up for 1 ... 2 minutes.
If the motor does not ignite after several unsuccessful
attemps at starting, move the speed control lever back
into stop position and pull the starting rope through
Important
slowly, 5 times. Then repeat the starting procedure.
3.3.3 Switching off the engine
Adjust engine speed control lever (1) to idle position.
1
min
max
B1799205.cdr
B1799206.cdr
Press motor stop button (4), until the motor stops running.