3. Operation
3.4 Engine operation — Honda
3.4.1 Starting the engine
To prevent engine damage through oil deficiency, the
engine is provided with a low oil warning system. If the
oil level is too low, the engine switches off automati-
Important
cally (the engine switch remains in the «ON»-position).
ON
GX 120_001.cdr
Move fuel tap (1) to «ON».
CLOSE
CLOSE
GX 120_002.cdr
Move choke lever (2) to «CLOSE».
3
GX 120_003.cdr
Adjust engine speed control lever (3) to «MAX» (full load).
1
ON
2
MAX
43
ON
ON
GX 120_004.cdr
Move engine switch (4) to «ON».
GX 120_005.cdr
Pull starter handle (5) slightly until resistance is felt, then pull
out sharply.
Do not allow starter handle to rebound against the
engine. Guide starter cable back by hand to reset
position.
Attention
Do not operate choke lever (2) if engine is warm or
at high outside temperature.
4
5
ON