Herunterladen Inhalt Inhalt Diese Seite drucken

Installing The Perimeter Wire - Stihl MOW 5.0 EVO Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
English
8
Installing the Perimeter
Wire
8.1
General requirements
Checking routing of perimeter wire and guide
wire in the mowing area
b
1
a
2
► Make sure that the mowing area along the
perimeter wire and the guide wire is flat and
clear of obstacles as far as possible along the
following widths:
Perimeter wire (1)
– Toward the outside: a = 37 cm (length:
®
1x iMOW
Ruler)
– Toward the inside: b = 1.2 m
Guide wire (2)
– Toward the right in the direction of travel
toward the docking station: a = 37 cm
(length: 1x iMOW
– Toward the left in the direction of travel
toward the docking station: c = 1.2 m

Installing the Perimeter Wire

► Install the perimeter wire clockwise starting at
the docking station.
► Do not kink, cut, put tension on or cross the
perimeter wire.
► Make sure that the perimeter wire does not
cross over a guide wire.
► Exception: When installing a corridor, the
guide wire must cross the perimeter wire.
► Keep a minimum distance of 1 m to perimeter
wires of adjacent robot mower installations.
► Make sure that the length of the perimeter wire
does not exceed 850 m.
► Do not route the perimeter wire and guide wire
at different depths in the soil.
68
c
®
Ruler)
8 Installing the Perimeter Wire
Attaching perimeter wire and guide wire
a
► Use anchoring stakes to secure the perimeter
wire and guide wire so that the following con‐
ditions are met:
– The maximum distance between fixing pins
must not exceed a = 1 m.
– The perimeter wire and guide wire lie flat on
the ground in all areas.
– The anchoring stakes are sunk completely
into the ground.
Installing Wire Reserves
Wire reserves make it easier to correct installed
wire and give some leeway for future adapta‐
tions.
Examples:
– A bed is extended and blocked off.
– Bushes and shrubbery grow and the perimeter
wire must be installed around the plants in a
larger arc.
– The perimeter wire was cut too short at the
docking station and cannot be connected.
One or several wire reserves can be planned
and installed.
► Route a = 1 m of perimeter wire in parallel and
closely together around 2 fixing pins without
the perimeter wires crossing over each over.
► Secure the wire reserve at the center using
two additional fixing pins.
a
0458-012-9601-A

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mow 6.0 evoMow 7.0 evo

Inhaltsverzeichnis