Maintenance instructions LA 60P-TUR

2.4 Condensate drain hose

Visual inspection:
Has it been securely fitted to the condensate tray drain?
Has the hose been routed so that it descends?
There must be no kinks in the hose!
Has unpressurised drainage been ensured?
Can the liquid drip freely?
Is the hose damaged?
Hose routed correctly
NOTE
If installed above a gravel bed, the end of the condensate hose
where the liquid drips out must be laid in the gravel bed down
to the frost line
. The depth can vary according to the
climatic region. The regulations of the countries in question
must be observed.
4
Fig. 2.3:Condensate drain when installed above a gravel bed
NOTE
The siphon must have a minimum sealing liquid level of
300 mm. The condensate drain must be checked to ensure
that it is working correctly and has no leaks.
4
Fig. 2.4:Condensate pipe in channel over siphon
www.glendimplex.de
NOTE
If it is a free-standing installation, a ground clearance of at
least 40 cm must be ensured between the end of the
condensate hose where the liquid drips out and the ground.
Fig. 2.5:Condensate drain for a free-standing installation
452167.66.43-EN · FD 0008
Free drainage downwards