4. Scope of delivery, special accessories and replacement parts

4.1 Scope of delivery

- Case with foam inlays and operating instructions (CD-ROM)
- Connecting line for delivery module (adapter)
- Extension cable (for metering module test)
- Sealing plug (metering module electrical connection)
- Test pipe for metering module (return)
- Test pipe for metering module (inlet)
- Metering module return sealing pipe
- Metering module inlet sealing pipe
- Graduated beaker set (0.5 l / 0.25 l / 0.1 l) incl. retaining strap
- Test gauge 1 <test metering module> DNOX 2.1 (refer also to Section 5)
- Pressure gauge, -100...900 kPa (-1...9 bar)
- Handheld refractometer (no space provided inside the case)
- Test pressure pipe Y-hose
- Oil test strips (with container)
- Scales with digital display, range 0...500 g,
resolution 0.1 g, accuracy +/- 0.1 g (supplied without batteries)
- Calibrating weight 500 g +/- 0.025 g

4.2 Special accessories (to be ordered separately)

- Test gauge 2
test metering module> DNOX2.2
<

4.3 Replacement parts

- Graduated beaker retaining strap
5. Reference standard/test equipment monitoring, test gauge
replacement intervals

5. 1 Reference standard/test equipment monitoring

The calibrating weight for the digital scales is a reference standard, the pressure gauge is an
item of test equipment. The condition and accuracy of these must be checked by an authorized
calibration service at certain intervals. A calibration certificate will then be issued.
Reliable calibration of the digital scales may not be possible in the event of failure to comply
with the checking intervals for the weight.
The same applies to the pressure gauge. Incorrect pressure value displays will lead to
erroneous assessment and removal.
The user is responsible for stipulating the re-calibration intervals.
The standard re-calibration intervals are between 6 months and 2 years depending on
frequency of use and the desired level of safety.
1 year is generally recommended.
5.2 Test gauge/test metering module replacement intervals
The test metering module is a test gauge which has to be replaced at fixed intervals. The
system cannot be reliably tested if the replacement intervals are not observed.
0 986 610 317
0 986 610 294
0 986 610 451
0 986 610 452
0 986 610 453
0 986 610 454
0 986 610 457
0 986 610 458
0 986 610 460
0 986 610 464
0 986 610 510
0 986 610 511
0 986 610 523
0 986 610 521
0 986 610 838
0 986 610 839
0 986 610 522
0 986 610 419
11