Herunterladen Inhalt Inhalt Diese Seite drucken

Overview Of The Terminal Connections - Bosch MS 200 Installationsanleitung

Vorschau ausblenden Andere Handbücher für MS 200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
28 | Mounting
3.2.4

Overview of the terminal connections

This overview shows examples of system components that can be
connected for all of the terminals of the module. The components
identified with * (such as VS1 and VS3) of the system are possible
alternatives. Depending on the module's use, one of the components is
connected to the "VS1/PS2/PS3" terminal.
VS1,
PS2, PS3
N 74 75
N 74 75
N 74 75
4
74 75
N
N
M
M
VS3*
N L
N L
N L
M
M
M
PS5
VS2
PS3
Legend to the figure above and Fig. 20 to 41 (without terminal designation).:
Solar thermal system
Function
Additional functions in the solar thermal system (shown in
grey)
Transfer or primary store system
Transfer or primary store function
Additional functions in the transfer or primary store system
(shown in grey)
Earth lead
Temperature/temperature sensor
BUS connection between heat source and module
No BUS connection between heat source and module
[1]
1st cylinder
[2]
2nd cylinder
[3]
3rd cylinder
230 V AC Mains voltage connection
BUS
EMS 2/EMS plus BUS system
M1
Pump or valve controlled via temperature differential
controller
PS1
Solar circuit pump for collector array 1
PS3
Cylinder primary pump for cylinder 2 with pump
(solar thermal system)
PS4
Solar circuit pump for collector array 2
PS5
Cylinder primary pump when using an external heat
exchanger
PS6
Cylinder transfer pump for transfer system (solar thermal
system) without heat exchanger (and thermal disinfection)
PS7
Cylinder transfer pump for transfer system (solar thermal
system) with heat exchanger
PS9
Thermal disinfection pump
PS10
Active collector cooling pump
PS11
Pump on the heat appliance side (primary side)
PS12
Pump on the system side (secondary side)
6 720 815 257 (2014/10)
120/230 V AC
PS5
VS2
PS4
N
63
N 43
44
N 63
120/230 V AC
PS1
VS1/PS2/PS3
120/230VAC 120/230VAC
N L
N
L
N 74
75
N 63
N L
N L
M
M
230 V AC 230 V AC
VS1*
PS1
More complex solar systems can be created in combination with a
second solar module. Terminal assignments deviating from the terminal
overview are possible ( connection diagrams with system
schematics).
MS 200
≤ 24 V
TS4 TS5
TS6
TS7
TS8
IS2
1 2 1 2
1 2
1 2
1 2
1 2 3 4 1
≤ 24 V
TS3
IS1
OS1
TS1 TS2
1 2 1 2
1 2
1 2 3 4 1
2 3
1 2 3
PWM
0-10V
TS1 TS2 TS3
TS13
PS1
V
WM1
PS13
DHW circulation pump
MS 100
Module for standard solar thermal systems
MS 200
Module for extended solar thermal systems
TS1
Temperature sensor for collector array 1
TS2
Temperature sensor at bottom of cylinder 1 (solar thermal
system)
TS3
Temperature sensor at middle of cylinder 1 (solar thermal
system)
TS4
Temperature sensor for heating return to the cylinder
TS5
Temperature sensor at bottom of cylinder 2 or swimming
pool (solar thermal system)
TS6
Heat exchanger temperature sensor
TS7
Temperature sensor for collector array 2
TS8
Temperature sensor for heating return from the cylinder
TS9
Temperature sensor at top of cylinder 3; only connect to
MS 200 if the module is installed in a BUS system without a
heat appliance
TS10
Temperature sensor at top of cylinder 1 (solar thermal
system)
TS11
Temperature sensor at bottom of cylinder 3 (solar thermal
system)
TS12
Temperature sensor in solar collector flow (heat meter)
TS13
Temperature sensor in solar collector return (heat meter)
TS14
Heat source temperature sensor
(temperature differential controller)
TS15
Heat sink temperature sensor
(temperature differential controller)
TS16
Temperature sensor at bottom of cylinder 3 or swimming
pool (solar thermal system)
TS17
Temperature sensor at heat exchanger
TS18
Temperature sensor at bottom of cylinder 1 (transfer /
primary store system)
OS2
2 3
BUS
BUS
1 2
1 2
BUS BUS
TS4 TS5 TS6
TS7
1 2 3
PWM
0-10V
TS8
TS12
PS3
6 720 807 456-24.2O
MS 200

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ms 100

Inhaltsverzeichnis