START-UP

After the product has been ASSEMBLED and LEAK TESTING has been carried out
successfully, it is immediately ready for operation.
1. All shut-off fittings on the gas devices must be closed.
2. Slowly open the gas withdrawal valve.
3. Observe the assembly and operating instructions of the gas device!
Connecting a gas cylinder with emergency supply set; double-stage tank regulator
type BHK 052 or type BHK 052B
close
1. Close the gas withdrawal valve on the
overfill sensor on the gas tank.
close
3. First screw the emergency supply connector on to the emergency supply set and then
connect it with the gas cylinder (spanner width 30).
Artikel-Nr. 05 239 50 l
open
2. Unscrew the sealing nut of the
emergency supply with a suitable open-
end spanner (width 19).
close
25 / 120