LEAK TESTING

Serious burns to the skin or material damage.
Do not use an open flame to check for leaks!
1. Close all shut-off fittings on the connected consumption equipment.
2. Open the gas cylinder valve on the operating side and reserve side.
3. Read the pressure on both pressure gauges and close the gas cylinders again.
4. Spray all screw connections on the hose assembly/assemblies,
gas cylinder valves on the product and others with a foam producing
substance according to EN 14291 (e.g. leak detector spray,
order no. 02 601 00).
5. Check the leak-tightness by seeing whether bubbles form in the foam-producing
substance.
6. If the pressure gauges still show the same pressure after 5 minutes, the gas system
is sealed.
leaks cannot be stopped then the product must not be used.
The liquefied gas unit must be checked for leaks by an expert* before the first start-up, during
checking and maintenance work, before the re-start and after important changes and repair
work. See USER QUALIFICATION!*
Observe EN 1949 and, in Germany, DVGW worksheet G 607.
Observe EN ISO 10239 and, in Germany, DVGW worksheet G 608.
Observe the applicable national installation regulations for LPG systems.

START-UP

After the product has been ASSEMBLED and LEAK TESTING has been carried out
successfully, it is immediately ready for operation.
1. Connect the gas cylinder(s) and check the hoses.
2. Slowly open the gas cylinder valve(s).
3. Observe the assembly and operating instructions of the connected devices.
If you open the gas cylinder valves too quickly, this may result in a short-term
pressure increase, which causes the pressure relief valve PRV to respond.
The LPG cylinder(s) must be upright when gas is being withdrawn.
Gas is withdrawn only from the gaseous phase.
Protect gas cylinder(s) against radiant heat or heat from heating appliances.
Observe the installation regulations in the respective countries.
Close the gas cylinder valve(s) for storage and transport.
The protective cap serves as additional protection against the escape of gas in the event of
leaks.
Mount the protective cap to secure the gas cylinder valve(s) during transport.
8 / 12
Risk of burns or fire!
If more bubbles form, re-tighten the connections (see ASSEMBLY). If the
Caramatic BasicTwo
part no. 02 018 51d