4.12.1 Malfunctions

Malfunction
Flashing of the
display
Screen doesn't
refresh
No data visible
Version 1.1.4 - 2022-9-14
Cause / possible effects
Voltage too low
Operation mode "S" is active
Disturbance in the circuit
No power supply
Battery voltage less than 3V
Translation of original instruction
Solution
Change battery
Disable the operation mode "S".
Remove the battery, wait 30 seconds and
reinsert the battery.
Clean battery contacts
Replace battery