Start-Up Connection; Cleaning Of Conveyor-Track Lubrication System; Diaphragm Metering Pump Emp Ii; Front View: Diaphragm Metering Pump Emp Ii E60 - ECOLAB Lub-O-Mat 2,5 Betriebsanleitung

Dosierstation für die bandschmierung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.
Start-up
6.1
Connection
Before initial start-up, the
The power supply 230 V/50 Hz is provided via the main switch.
The empty signal connector for the suction lance is connected directly to the metering pump
(3-pin plug) of the
manual for the EMP II E60 metering pump, article no. 417101339.
6.2

Cleaning of conveyor-track lubrication system

• Before the start-up of the system, all components have to be rinsed with hot water (most
effective by hot water) as the system has to be cleaned from left particles of the
mechanical treating.
• For the cleaning of the pipe-system it has to be removed 1 nozzle per bar. In this way
optimum conditions of the flow can be reached and nozzles as well as ball-valve filters are
protected against dirt.
• Before starting the filling-system (facility) we recommend a base-cleaning of the
conveyors. Dirty conveyors can cause problems during the start-up of the lubrication
system and a risk of wearing at the chains and slide-bars especially with dry-lubrication
systems.
• At change of belt lubricant we recommend a base-cleaning of the complete system.
• Please refer to the product recommendations from ECOLAB.
6.3

Diaphragm metering pump EMP II

See operating manual for the EMP II E60
manual for EMP E60 on CD.
6.3.1

Front view: Diaphragm metering pump EMP II E60

417101637_Lub-O-Mat
Lub-O-Mat
must be installed as part of the system as a whole.
Lub-O-Mat
(see chapter 6.3.1). Connector configuration: see the operating
Pos.
1
2
3
4
5
6
I
II
III
IV
Fig. 6.1
PLUS
diaphragm metering pump, and complete
Description
Control knob for setting the stroke length
Menu/Exit, up arrow key
Menu/Exit, down arrow key
Start/Stop key (Enter function)
Test-key
Graphical display
Input for low-level advance warning and empty report
Input for pulse- / standard signal and metering lock
Output for empty report, fault report and stroke signal
Mains power supply
- 38 -
Rev. 03-07.12